Thermo Products OH6FA072D48N OH8FA119D60, Speed vs. color code for PSC Motor Low = Red

Models: OH8FA119D60B OH8FA119DV5B OH6FX072DV4R OH6FA072DV4N OH6FA072D48N OH8FA119D60R OH8FA119DV5R

1 79
Download 79 pages 47.9 Kb
Page 37
Image 37
OH8FA119D60

OH8FA119D60

 

ALTERATIONS REQ’D FOR A/C @ DESIGN EXTERNAL STATIC PRESSURE

 

 

 

 

COOLING UNIT

 

 

HTG Speed by Input

 

 

 

 

Recommended CLG Speed

 

 

 

 

 

 

 

Low

Mid

High

 

 

 

 

 

 

 

 

 

 

 

 

Fire

Fire

Fire

 

 

 

 

 

 

 

 

36,000

 

 

 

L/ML

 

ML/MH

 

MH/H

 

 

Low (L)

 

 

 

 

42,000

 

 

 

L/ML

 

ML/MH

 

MH/H

 

 

Med Low (ML)

 

 

 

48,000

 

 

 

L/ML

 

ML/MH

 

MH/H

 

 

Med High (MH)

 

 

 

60,000

 

 

 

L/ML

 

ML/MH

 

MH/H

 

 

High (H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed Tap\ Static

 

 

 

 

Furnace Airflow (CFM) vs. External Static pressure (in. WC.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure

0.1

 

0.2

 

 

0.3

 

0.4

 

0.5

 

0.6

0.7

 

Low

1254

 

1254

 

1251

 

1246

 

1221

 

1189

1126

 

ML

1473

 

1464

 

1460

 

1437

 

1415

 

1377

1329

 

MH

1733

 

1731

 

1718

 

1705

 

1686

 

1660

1627

 

High

2300

 

2243

 

2224

 

2166

 

2099

 

2048

1754

Furnace Motor Current Draw (Amps)/Watts vs. External Static pressure (in. WC.)

Low

6.6/648

 

6.6/648

6.4/639

6.2/630

6.0/612

5.8/592

5.4/565

ML

7.6/772

 

7.2/739

7.1/730

6.8/704

6.6/683

6.3/661

6.1/641

MH

9.0/908

 

9.0/905

8.7/888

8.5/871

8.3/842

8.0/818

7.7/796

High

12.5/1270

 

11.7/1200

11.2/1150

10.7/1110

10.2/1060

9.7/1020

9.2/969

 

 

 

 

 

 

 

 

 

Speed Tap\ Static

 

High Fire Temperature Rise vs. External Static pressure (in. WC.)

 

 

 

 

 

 

 

 

 

Pressure

0.1

 

0.2

0.3

0.4

0.5

0.6

0.7

Low

98

 

98

98

99

101

103

109

ML

83

 

84

84

86

87

89

93

MH

71

 

71

72

72

73

74

76

 

High

53

 

55

55

57

59

60

70

 

Speed Tap\ Static

 

Mid Fire Temperature Rise vs. External Static pressure (in. WC.)

 

 

 

 

 

 

 

 

Pressure

0.1

0.2

0.3

0.4

0.5

0.6

0.7

Low

88

88

88

89

90

93

98

ML

75

75

75

77

78

80

83

MH

64

64

64

65

65

66

68

High

48

49

50

51

52

54

63

Speed Tap\ Static

 

Low Fire Temperature Rise vs. External Static pressure (in. WC.)

 

 

 

 

 

 

 

 

Pressure

0.1

0.2

0.3

0.4

0.5

0.6

0.7

Low

75

75

75

75

77

79

83

ML

64

64

64

65

66

68

70

MH

54

54

55

55

56

56

58

High

41

42

42

43

45

46

53

Figure 19B: Heating speed by input

Speed vs. color code for PSC Motor:

Low = Red

Med-Low = Blue

Med-High = Yellow

High = Black

34

Page 37
Image 37
Thermo Products OH6FA072D48N, OH8FA119DV5R, OH8FA119D60R, OH6FA072DV4N Speed vs. color code for PSC Motor Low = Red