Thermo Products PGT16-160 Two Piece Mounting Plate, Side View Burner Insertion Illustration Pgt

Models: PGL33-250 PGL39-400 PGL37-312 PGT11-125 PGL20-180 PGT5-100 PGT16-160

1 38
Download 38 pages 37.07 Kb
Page 14
Image 14
TWO PIECE MOUNTING PLATE

All installations and services must be performed by qualified service personnel.

TWO PIECE MOUNTING PLATE

When mounting the burner, the upper mounting plate must be removed to provide access to the area in front of the combustion chamber. The combustion chamber can then be moved forward or backward slightly to allow for adjustment in positioning the burner tube. Do not allow the burner tube or end cone to physically touch the chamber, as excessive heat transfer could result in distortion of the tube or end cone, or both.

Once the burner tube is properly positioned, at most 1/4 inch back from the inside surface of the combustion chamber wall, the loose-fill insulation that is included should be lightly placed around the burner tube between the front of the combustion chamber and the burner mounting plate. (DO NOT PACK THE INSULATION DOWN). The loose-fill insulation should be placed in such a fashion that the surface of the insulation is sloped from the top of the combustion chamber to the top of the lower mounting plate. The purpose of the loose insulation is to help protect the burner tube, mounting plates and vestibule area from internal temperatures.

NOTE: Do not place loose insulation around chamber sides and back.

(SIDE VIEW)

BURNER INSERTION ILLUSTRATION (PGT)

CAUTION: When installing the burner, it should be noted that the loose fill insulation and fiber chambers are made with ceramic fibers. Currently, there are no known chronic health effects in humans associated with long term exposure to ceramic fibers. The International Agency of Research on Cancer (IARC) based on its review of studies that injected ceramic fiber into the abdomens of hamsters and rats have classified fibrous glass wool, mineral wool (both rock wool and slag wool) and ceramic fiber as group 2B carcinogens. A group 2B agent is considered by IARC