5.2. Connecting 32 or More Combination Cameras

Connect the Combination camera's control cable to the unit's Slave Connection Terminal, making sure to match their polarities.

Camera control terminal

Remote controller

C-RM500

GND

Shielded twisted-pair cable

Termination switch: ON

 

MASTER

 

SLAVE

 

C-IF500

IN

OUT

 

A

B

C

D

GND

GND

TERMINATION

GND

GND

GND

GND

 

 

OFF ON

 

 

 

 

 

 

 

 

 

 

Caution

Up to 31 C-CC501, C-CC504, C-CC551, or C-CC554 Combination Camera can be connected to each Slave Terminal A-D.

Combination camera

Ch 1

Ch 2

Ch 31

Termination switch

Termination switch

Termination switch

OFF

OFF

ON

Combination camera

Ch 32

Ch 33

Ch 62

Termination switch

Termination switch

Termination switch

OFF

OFF

ON

[Connection cables]

Recommended cable type: CPEV-S type (shielded twisted-pair cable) thicker than 0.65 mm in diameter.

If multiple cameras are connected to a single terminal, the total of each cable distance between connected equipment must be 1.2 km or less.

Interface unit

C-IF500

a

Combination

 

Combination

camera

 

camera

b

a + b + c < 1.2 km

c

Combination

camera

[Termination switch setting]

Set the unit's termination switch to ON when the unit and the C-RM500 Remote Controller are connected in a matched pair in the system.

Make sure that the termination switches of the cameras connected to the system are set as follows.

Cameras other than the last connected camera: Termination switch OFF

Last connected camera:

Termination switch ON

Interface unit

C-IF500

Combination

camera

Terminal switch

OFF

Combination

camera

Terminal switch

OFF

Combination

camera

Terminal switch

ON

6

Page 6
Image 6
TOA Electronics C-IF500 Connecting 32 or More Combination Cameras, Connection cables, Termination switch setting