3-9
Chapter 3: SYSTEM SETTINGS (NX-100 SETUP PROGRAM)
5.2. Menu
5.2.1. File
Save in setting file format (Ctrl+S): Saves scanned unit data to the PC in unit setting file format ([IP
address].cfg)
Exit: Exits the program.
Important
The [Save in setting file format] function is used to set broadcasts in the system settings after the unit scan is
complete. Selecting [Save in setting file format] writes the setting contents into the data folder. The contents of
the unit setting file include only the IP address, subnet mask, default gateway, unit name, and Web server port
number.
When broadcast contents have previously been set and saved using the System Setting Tool, these earlier
system settings will be erased if [Save in setting file format] is selected.
If system setting has already been performed, take the following measures to prevent erasure of the setting
contents:
1. Upon completion of System Setting Tool settings, copy and save the data folder under a different
name.
If the data folder is copied, the unit setting file can be written into the NX-100 and the NX-100S after
copying the renamed folder to the data folder, even when [Save in setting file format] is selected.
2.After Unit Scanning Tool settings have been performed, use the System Setting Tool after
uploading the settings, but without executing [Save in setting file format].
This prevents the unit setting file in the data folder from being overwritten.
5.2.2. Scan
Unit scan: Scans the units connected to the LAN.
Change settings: Uploads the settings of the selected unit.
IP address: Automatically assigns an IP address and performs related settings.
Auto assignment: Automatically assigns an IP address to the selected unit.
Assignment range setting: Sets the IP address range to be used in automatic IP address assignment.
Subnet mask setting: Sets the same subnet mask to the selected units.
Default gateway setting: Sets the same default gateway to the selected units.
Select all (Ctrl+A): Selects all of the units scanned.