Millivolt Appliances - Appliances with Millivolt systems will be fitted with the gas control valve shown in Figure 3.

Electronic Appliances - Appliances with electronic systems will be fitted with the electronic valve shown in Figure 4.

Millivolt Appliances - To light millivolt ap- pliances refer to Figure 2. Detailed lighting instructions are found on Pages 18 & 19 . Mil- livolt appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.

Once the pilot is lit, the main burner may be turned ON and OFF using wall switch, remote control, optional on unit rocker switch (FRS), or wall thermostat. To operate: Toggle the switch between its ON and OFF positions.

If your millivolt appliance is equipped with an optional remote switch kit (wall switch, remote control, rocker switch, or wall thermostat) and the pilot is lit, the appliance main burner may be turned on and off using the optional switch.

Note: To prevent excessive resistance in burner circuit (which can cause burner operation prob- lems), only one burner control switch should be wired to valve.

Electronic Appliances -

To light electronic appliances refer to the detailed lighting instructions found on Pages 20 & 21 of these instructions. Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.

5 Inch

 

 

 

 

Pipe Nipple

Gas Flex Line

Valve

Piezo

Spring Door Latch

Figure 2

 

 

 

 

Main Gas Control Knob

 

 

Gas Inlet

 

 

 

 

 

OT

 

 

 

 

 

 

IL

 

 

 

 

 

 

P

 

 

 

 

T

O

N

 

 

 

 

 

 

 

 

 

 

 

 

it

 

 

TH

 

 

O

 

WO L

 

 

 

L

 

 

 

 

 

I

 

 

 

 

 

 

P

 

 

 

 

 

 

 

FFO

H I

 

TP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TPTH

 

Gas

IN

OUT

 

 

 

 

 

Manifold Pressure

 

 

 

Outlet

Inlet

 

 

 

 

Port

Variable Flame

 

 

 

Pressure

 

 

 

Port

 

 

Height Adjustment

Terminals TPTH, TP & TH

Figure 3

 

 

 

 

 

SIT Millivolt

Gas Valve

If your electronic appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control.

If your electronic appliance is not equipped with a wall switch or remote control, the main burner must be turned off and on with a gas control switch located in some other location by the installer. Contact the installer for directions.

Variable Flame Height Adjustment

Pilot Stage

Terminal

Ground (TP)

TP

Gas Outlet SIT Millivolt

To Burner

Pressure-Tap (Inlet)

 

IN

TH TP

 

LO

HI

TH

OUT

 

 

VENT

Pilot Gas

Outlet

PILOT

Supply Gas

IN

Inlet

1. All millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings while the appliance is in operation. Adjust the flame height as desired after lighting the appliance by rotating the variable adjustment control knob (HI/LO) located on the front of the valve (refer to Figures 3 & 4 ).

Burner Stage

Regulator

Pressure-Tap

Terminal

Mounting Screw

(Manifold)

Figure 4

 

Dexen Electronic Gas Valve

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Page 4
Image 4
TOA Electronics SLDVT-40, SLDVT-35 manual Variable Flame Height Adjustment, SIT Millivolt, Dexen Electronic Gas Valve