If you are having a problem with the timer, check the following symptoms, possible causes and remedies.

If the problem cannot be resolved, or you would like assistance with any Toro irrigation product, call our toll-free Toro Help Line at 1-800-367-8676, Monday through Friday, 7:30 a.m. – 4:00 p.m. (Pacific Time).

Symptom

Possible Cause

Remedy

 

The display is blank and the

Main power is disconnected.

Check the transformer connections

 

timer does not operate.

 

(indoor model) or circuit breaker

 

 

 

service panel (outdoor model).

 

 

 

 

 

Watering programs start at

Watering programs have overlapping

Shorten zone run times (p. 28) and/or

 

unscheduled times.

schedules.

space start times farther apart (p. 27).

 

 

 

 

 

Watering zone does not turn on.

Faulty control valve wire connections.

Check the wire connections at the

 

 

 

control valve and timer.

 

 

Automatic Circuit Protection has

Check for faulty valve solenoid and

 

 

disabled the zone.

replace if necessary.

 

 

Zone run time is turned Off.

Enter a zone run time (p. 28)

 

 

 

 

 

Watering zone does not turn off.

Control valve problem.

Inspect, clean and/or repair valve

 

 

 

as needed.

 

An Program restarts unexpectedly

More than one start time on the

Remove additional program start

 

after the completion of an

program.

times (p. 27).

 

automatic operation.

Season Adjust setting greater than

Review Season Adjust factor (p. 34).

 

 

 

 

100%.

 

 

 

 

 

 