Multi-Manual Mode

Up to six selected stations can be operated at the same time using Multi-Manual mode. A temporary run time from 1 to 59 minutes is given to each station for this operation.

Caution: Prior to Multi-Manual operation, ensure that combined current draw of all stations operating at the same time (including pump relay) does not exceed 3.2 Amps (holding).

1.Press to select the Multi-Manualindicator. The Program indicator will light and Station number 01 will be shown (flashing)

in the left display.The right display will show 00 run time.

2.Press or as needed to select the desired station.

3.Press – The Run Time digits will begin flashing.

4.Press or as needed to select desired Run Time (01 – 59)

ENTER

5.Press – Selected station will start.

START

6.Repeat steps 2 5 to start up to five additional Stations. If the same run time is desired, skip steps 3 and 4.

Note: Any additional stations entered while six stations are in operation will be ignored.

Note: After 1 minute has elapsed, the displays will begin alternating between the time/day and the program status, showing (in sequence) each operating station and its remaining run time.