8.0System Status and Control Indicators

1600EP Single Phase Uninterruptible Power Supply Systems Guide Specifications

3.6, 6.0, 8.0, 10.0, 14.0, 18.0, 22 kVA

8.0System Status and Control Indicators

8.1

Panel

 

 

The UPS shall have a panel on the front for complete

monitoring control of UPS.

Operation panel features:

1)Run/Stop button

2)AC input voltage indicator

3)Inverter status indicator

4)Alarm indicator

5)Fault indicator

6)Liquid Crystal Display (LCD)

The UPS shall have menu driven LCD that displays operating conditions, warning messages and fault indication messages for the unit.

Operating Conditions Display:

1)Input voltage

2)Output voltage

3)Input frequency

4)Output frequency

5)Output current

6)Battery voltage

7)Battery test results

8)Output voltage adjustment

9)UPS ON/OFF Line

Warning messages:

1)Overload

2)Current limit

3)Emergency power off

4)Battery discharge

5)Battery Low

6)Input undervoltage

7)Battery not good

Fault Messages:

1)DC undervoltage

2)DC overcurrent

3)DC overvoltage

4)Overheat

5)UPS overload

6)Inverter undervoltage

7)Inverter overvoltage