10. GENERAL MAINTENANCE
10.4 Threshold Setting
■Threshold setting procedure (For firmware version 2.5 or earlier)
1Turn the power on.
2Load the
3 Press the [PAUSE] key once.
4 Hold down the [PAUSE] key for more than 3 seconds and it will begin to feed. After it has fed the 2 label, release the [PAUSE] key.
5 Press the [RESTART] key for ON LINE mode.
6 Threshold setting is now completed.
NOTES: 1. If the [PAUSE] key is not held down for more than 3 seconds in PAUSE mode the threshold will not be set.
2.If the [PAUSE] key is released before 2 labels have been issued the setting may not be correct and will have to be
10.5Auto Ribbon Saving Mode
Auto ribbon saving function is activated when it is selected by DIP switch (Refer to page
NOTE: According to the relation between the outer diameter of rewound ribbon and print speed, ribbon loss per saving varies as follows:
Print speed | Ribbon loss | |
3"/sec. | Approx. 5 mm | |
5"/sec. | Approx. 8 mm |
|
|
|
|
8"/sec. | Approx. 17 mm |