6-27
EM18-33010A
6. DIAG. TEST OPERATION
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables
a fast forward.

2. A changed control code is stored in memory by pressing the [PAUSE] key.

3. When “AUTO”, “ESC, LF, NUL”, or “{, ,}” is selected, be sure to select the Non-

transmissive ribbon in the ribbon type selection operation.

4. When “MANUAL” is selected, be sure to specify all the control codes 1 to 3. Failure

to do this disables selection of “MANUAL”.

SVO8A1002 : Jan. 19, '98
6.3 PARAMETER SETTING MODE
6.3.8 Control Code Selection
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key.
Press the [PAUSE] key nine times.
Select control code with the
[FEED] key or [RESTART]
key. (See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Press the [PAUSE] key.
Continued on Section 6.3.9
Ribbon type selection.
<1 DIAGNOSTIC V1.OA
>
<2 PARAMETER SET
>
CO E AUTOD
When {MANUAL} is
selected, go to A
on the next page. B
AUTO: (Automatic selection)
ESC, LF, NUL: (Manual selection)
{ , , } : (Manual selection)
MANUAL: (control codes should be specified.)