43
11.2.711.2.711.2.711.2.7 GROUP:PROTECTION FUNCTION PARAMETERSGROUP:PROTECTION FUNCTION PARAMETERSGROUP:PROTECTION FUNCTION PARAMETERSGROUP:PROTECTION FUNCTION PARAMETERS
Register Function / Title Bank Mask Adjustment Range Multiplier
11F DYNAMIC BRAKING
SELECTION 0 / 1 0003 0000: no dynamic braking (0)
0001: with dynamic braking, no DB R
overload trip (1)
0003: with dynamic braking and
DBR overload trip (2)
120 2
BRAKING RESISTOR
VALUE 0 / 1 FFFF 000A 2710 (1.0 1000) 0.1
121 BRAKING RESISTOR
POWER RATING 0 / 1 FFFF 0001 EA60 (0.01 600.00) 0.01
122 OVERVOLTAGE STALL
PROTECTION 0 / 1 0004 0000: ON (0)
0004: OFF (1)
123 DC INJECTION START
FREQUENCY 0 / 1 FFFF 0000 ��� 2EE0 (0.00 120.00) 0.01
124 Other
than 0 DC INJECTION
CURRENT
MAGNITUDE
0 / 1 00FF 0000 0064 (0 100) 1
125
DC INJECTION
TIME 0 / 1 00FF 0000 0064 (0.0 10.0) 0.1
126 FWD/REV DC INJECTION
PRIORITY CTRL 0 / 1 0040 0000: OFF (0)
0040: ON (1)
127 MOTOR SHAFT
STATIONARY CTRL 0 / 1 0080 0000: OFF (0)
0080: ON (1)
128 EMERGENCY OFF MODE
SELECTION 0 / 1 0030 0000: Coast stop (0)
0010: Decelerated stop (1)
0020: DC injection stop (2)
129 2 EMERGENCY OFF DC
INJECTION TIME 0 / 1 00FF 0000 0064 (0.0 10.0) 0.1
12A NUMBER OF RETRY
ATTEMPTS 0 / 1 00FF 0000 000A (0 10) 1
12B Other
than 0 TIME BETWEEN
RETRY ATTEMPTS 0 / 1 00FF 0000 0064 (0.0 10.0) 0.1
12C REGENERATION POWER
RIDE-THROUGH 0 / 1 0008 0000: OFF (0)
0008: ON (1)
12D 1
REGENERATION
RIDE-THROUGH TIME 0 / 1 00FF 0000 00FA (0.0 25.0) 0.1
12E AUTO-RESTART (MOTOR
SPEED SEARCH) 0 / 1 0018 0000: OFF (0)
0008: On power failure (1)
0010: On ST make/break (2)
0018: Both (1) and (2) (3)
12F ELECTRONIC THERMAL
PROTECT LVL #1 0 / 1 00FF 000A 0064 (10 100) 1
130 OVERLOAD REDUCTION
START FREQ 0 / 1 FFFF 0000 0BB8 (0.00 30.00) 0.01
131 MOTOR 150% OVERLOAD
TIME LIMIT 0 / 1 00FF 0001 00F0 (10 2400) 10
132 OVERLOAD SELECTION 0 / 1 0030 0000: with motor overload trip,
without soft-stall (0)
0010: with motor overload trip and
soft-stall (1)
0020: without soft-stall or m otor
overload trip (2)
0030: with soft-stall, without m otor
overload trip (3)
133 STALL PROTECTION
ENABLE 0 / 1 0040 0000: ON (0)
0040: OFF (1)
134 0
STALL PROTECTION
CURRENT LEVEL 0 / 1 00FF 000A 00D7 (10 215) 1