Toshiba GD-1151, GD-1260, GD-1160, GD-1201 JOB Status button Cancel button, CED Nsfcsidis, Cfr, Mcf

Models: GD-1151 Model: GD-1150 GD-1201 GD-1260 GD-1160

1 90
Download 90 pages 1.91 Kb
Page 43
Image 43

Cancellation during the transmission

If the [STOP] button is pressed during the direct transmission or memory input, the display to confirm the cancellation appears. The communication is finished normally regardless of the presence/absence of the next page or mode changes by pressing the [STOP] button.

If the [STOP] button is pressed anytime except during the transmission of the image data, DCN is forcibly sent to terminate the communication.

Press the [JOB STATUS] button, and select the transmission job to cancel, then press the [CANCEL] button on the LCD display to cancel the memory transmission or polling transmis- sion.

Transmtter

[JOB STATUS] button

[CANCEL] button

Receiver

CED

NSF•CSI•DIS

NSS•TSI•DCS

Training

TCF

CFR

Image signal

EOP

3

MCF

DCN

© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved

GD-1150/1151/1200/1201/1160/1260

 

DIALING/COMMUNICATION CONTROL

3 - 7