-Communication end procedure

This procedure is to terminate the communication. The transmission rate is 1,200 bps. Transmitter

Signal name

Abbreviation

Function

Remarks

 

 

 

 

 

 

 

 

Sh signal

Sh

Short training

 

 

 

 

 

 

 

 

 

 

 

signal

 

 

 

 

 

Sh

Sh

 

 

 

 

 

 

 

 

 

 

ALT signal

ALT

-

 

 

 

 

 

 

 

 

 

E sequence

 

E

-

 

 

 

 

 

 

 

 

 

End of procedure signal

PPS-EOP

The transmission of one page

 

 

 

 

 

 

 

is completed.

 

 

 

 

 

 

 

 

 

 

Flag

flags

Maintains the synchroniza-

7E (H)

 

 

 

 

 

 

tion.

 

 

 

 

 

 

 

 

 

Disconnection signal

DCN

Informs to disconnect the line.

 

 

 

 

 

 

 

 

 

Receiver

Signal name

Abbreviation

Function

Remarks

 

 

 

 

 

 

 

 

Sh signal

Sh

Short training

 

 

 

 

 

 

 

 

 

 

 

signal

 

 

 

 

 

Sh

Sh

 

 

 

 

 

 

 

 

 

 

ALT signal

ALT

-

 

 

 

 

 

 

 

 

 

E sequence

 

E

-

 

 

 

 

 

 

 

 

 

 

Flag

flags

Maintains the synchroniza-

7E (H)

 

 

 

 

 

 

tion.

 

 

 

 

 

 

 

 

 

Message confirmation

MCF

Indicates that the image sig-

 

 

 

 

 

 

 

nal is received normally, and

 

 

 

 

 

 

 

the receiver is ready to

 

 

 

 

 

 

 

receive the next page.

 

 

 

 

 

 

 

 

 

GD-1150/1151/1200/1201/1160/1260