TOSHIBA
SECTION 4: Wiring

Standard Connection Diagrams

4 - 1

TOSVERT-130H3

STANDARD CONNECTION

MODEL 2035 TO 2330

MODEL 4055 TO 4330

DBR
PROGRAMMABLE
OUTPUT CONTACTS
250V, 2A MAX
PROGRAMMABLE
OUTPUT CONTACTS
250V, 2A MAX
PROGRAMMABLE
SIGNAL INPUT
PROGRAMMABLE
ANALOG INPUT
DIGITAL
OPERATION PANEL
L3(T)
F
RES
R
ST
S1
S2
L2(S)
(see note 3 below) S4
FLA
CC
FLB
R/CH-C
LOW-A
P24
FP
FM
AM
CC
AM FM
M
L1(R)
MCCB PA PB
+
+
AUTO
REF.
AUTO
REF.
-
-
IV
RX
CC
RR
PP
S3
T3(W)
T2(V)
T1(U)
R/CH-A
LOW-C
50mA MAX
PULSE OUTPUT
+ + PROGRAMMABLE
SIGNAL OUTPUT
0-1mA or 4-20mA
M
FLC
GND(E)
INPUT POWER SUPPLY
(see notes 1 and 2 below)
Potentiometer

NOTES:

1.) For drive models 2035 through 2330 use input power supply of 200VAC, 50Hz or

200-230VAC, 60Hz.

2.) For drive models 4055 through 4330 use input power supply of 380VAC, 50Hz or

400-460VAC, 60Hz.

3.) As an example, the "S4" terminal is shown above as an EMERGENCY OFF input. See

Section 8 for information on how to program the drive for this and other functions.