TOSHIBA
8 - 34

Parameter Tree (cont'd)

Protection Parameters Protection Parameters
(Continued) Pattern Run Control
Parameters Feedback Parameters Communication Setting
Parameters AM/FM Terminal
Adjustment Parameters Utility Parameters Utility Parameters
(Continued) Motor Parameters
142 160 175 243 260 275 279 296 316
Dynamic Braking
Selection Motor 150% Overload
Time Limit Pattern Run Selection Feedback Control
Selection RS232 Baud Rate FM Terminal Function
Selection Industrial Applications Current Units Selection Number of Motor Poles
143 161 176 244 261 276 280 297 317
Branking Resistor
Value Overload Selection Pattern Run Continue
Mode
Feedback Input Signal
Selection Number of Data Bits Frequency Meter
Adjustment
Standard Setting Mode
Selection Voltage Units
Selection Motor Rated Capacity
144 162 177-184 245 262 277 281 298 318
Braking Resistor
Power Rating Stall Protection Enable Pattern Group #1
Speeds #0 - #7 Proportional Gain Parity Setting AM Terminal Function
Selection Command Mode
Selection Blind Function
Selection Motor Type
145 163 185 246 263 278 282 299 319
Overvoltage Stall
Protection Stall Protection
Current Level Pattern Group #1
Number of Cycles Integral Gain Inverter ID Number Current Meter
Adjustment Frequency Mode
Selection Fundamental
Parameters #2 Blind Motor Rated Voltage
146 164 186-193 247 264 283 300 320
DC Injection Start
Frequency Undervoltage Trip
Selection Pattern Group #2
Speeds #0 - #7 Anti Hunting Gain Communication
Selection
Panel Operation Mode
Selection Panel Control
Parameters Blind Mo tor Rated
Frequency
147 165 194 248 265 284 301 321
DC Injection Current
Magnitute Undervoltage Detect
Time Pattern Group #3
Number of Cycles Lag Time Constant Master/Slave Selection Pass Number Terminal Selection
Parameters Blind Motor Rated RPM
148 166 195-202 249 266 285 302 322
DC Injection Time Low Current Detect
Selection Pattern Group #3
Speeds #0 - #7 PID Lower Frequency
Limit RS485 Baud Rate CPU Version Speci al Control
Params Blind Auto-Tuning Ena ble
149 167 203 250 267 286 303 323
Fwd/Rev DC Inj.
Priority control Low Current Detect
Level Pattern Group #3
Number of Cycles PID Deviation Limit
Selection TOSLINE F10/S20
Command Input ROM Version Frequency Setting
Params Blind L oad Moment of Inertia
150 168 204-211 251 268 287 304
Motor Shaft stationary
control
Low Current Detection
Time Pattern Group #4
Speeds #0 - #7 PID Deviation Upper
Limit TOSLINE F10/S20
Monitor Output EEPROM Version Protection Function
Params Blind
151 169 212 252 269 288 305
Emergency Off Mode
Selection Output Short Circuit
Detection Select Pattern Group #4
Number of Cycles PID Deviatio n Lower
limit TOSLINE F10/S20
Comm Error Mode Inverter TypeForm Pattern Run Control
Params Blind
152 170 213 253 270 289 306
Emergency Off DC
Injection Time Overtorque Trip
Selection Speed #1 Continue
Mode PG Input Number of
Pulses RS485/12-Bit Binary
Bias, Gain Status Monit or #1
Display Select Feedback Contro l
Params Blind
153 171 214 254 271 290 307
Number of Retry
Attempts Overtorque Trip Level Speed #1 Drive Time PG Input Number of
Phases RS485/12-Bit Binary
point #1 Status Monitor #2
display Select Communication
Params Blind
154 172 215-242 255 272 291 308
Time Between Retry
Attempts Fault Trip EEPROM
Save Enable Speeds 2 - 15 Drive
Time Drooping Control
Enable RS485/12-Bit Binary
pt. #1 Freq Status Monitor #3
Display Select Industrial Appl: Pump
Params Blind
155 173 215 - 242 256 273 292 309
Regeneration Power
Ride Through Cooling Fan Control
Selection
Speeds 2-15 Continue
mode Drooping Control
Amount RS485/12-Bit Binary
point #2 Status Monitor #4
Display Select Industrial Appl: Fan
Params Blind
156 174 257 274 293 310
Regeneration Ride
Through time
Cumulative Run Timer
Alarm Setting Override Control
Selection RS485/12-Bit Binary
pt. #2 Freq
Frequency Units Scale
Factor Industrial Appl:
Conveyor Blind
157 258 294 311
Auto-restart (motor
speed search) Override Multiplier
Input Selection Frequency Display
Resolution Industrial Appl: Hoist
Blind
158 259 295 312
Electronic Thermal
Protect Level 1 Override Change
Multiplier ACC/DEC Time Units
Selection Industrial Appl:
Textiles Blind
159 313
Overload Reduction
Start Freq. Industrial Appl: Tools
Blind
314
AM/FM Adjustment
Params Blind
315
Motor Parameters
Blind
Specifications
Precautions
Wiring