Move up and down by pushing MENU UP, DOWN
Select the desired value by pushing DATA UP, DOWN
|
|
|
|
|
|
|
|
|
|
4 PROCESS1 | ||||
| GAMMA ON/OFF | ON | ||
| GAMMA | 0 |
| |
| BLACK GAMMA | NORMAL | ||
| KNEE POINT | 85% |
| |
| KNEE SLOPE | 8 |
| |
| M | PED | 0 |
|
| R | PED | 0 |
|
| B | PED | 0 |
|
| WHT CLIP | 109% |
| |
|
|
|
|
|
Gamma correction ON, OFF |
| |
Gamma correction level setting | ||
Black gamma correction setting | LOW, NORMAL, HIGH | |
Knee correction point | 70 to 100% | |
Knee correction slope | 1 to 16 |
|
Master pedestal setting | ||
Red pedestal setting | ||
Blue pedestal setting |
White clip 100 to 109%
(4. 1) Changing gamma correction ON/OFF
1Move the ÒÓ to GAMMA ON/OFF by pushing the [MENU UP], [MENU DOWN] buttons.
2Select either ON or OFF by pushing the [DATA UP], [DATA DOWN] buttons.
When ON is selected, menu will show the GAMMA, BLACK GAMMA, KNEE POINT and KNEE SLOPE selections. When OFF is selected, GAMMA, BLACK GAMMA, KNEE POINT and KNEE SLOPE are not displayed. So the setting for GAMMA, BLACK GAMMA, KNEE POINT and KNEE SLOPE cannot be made.
Move up and down by pushing MENU UP, DOWN
Select the desired value by pushing DATA UP, DOWN
|
|
|
|
|
|
| Gamma correction ON, OFF | ||
4 PROCESS1 | (FILE A) | ||||||||
|
| ||||||||
| GAMMA ON/OFF | OFF |
|
|
| Master pedestal setting | |||
| M | PED | 0 |
|
|
| |||
|
|
|
|
|
| ||||
| R | PED | 0 |
|
|
| Red pedestal setting | ||
| B | PED | 0 |
|
|
| Blue pedestal setting | ||
| WHT CLIP | 109% |
|
|
| ||||
|
|
|
|
|
| ||||
|
|
|
|
|
|
| White clip 100 to 109% | ||
|
|
|
|
|
|
|
|
|
Menu when GAMMA OFF is selected.
(4. 2) Changing gamma correction level
1Move the ÒÓ to GAMMA by pushing the [MENU UP], [MENU DOWN] buttons.
2Select the desired value of gamma correction level by pushing the [DATA UP], [DATA DOWN] buttons.
[DATA UP] Correction amount becomes larger.
Correction amount becomes smaller. [DATA DOWN]
* When OFF is selected in GAMMA ON/OFF selection line, the GAMMA display disappears, so it cannot be changed.
24