(b)Changing the automatic shutter detection (ratio between peak and average value) Move the “ ” to PEAK/AVE by pressing [MENU UP], [MENU DOWN] buttons.
Select the ratio between peak and average value by pressing [DATA UP], [DATA DOWN] buttons.
(Peak:Average)
The peak value increases by pressing [DATA UP]
00:10 05:05 10:00
The peak value decreases by pressing [DATA DOWN]
(c) Changing the automatic shutter response speedMove the “ ” to SPEED by pressing [MENU UP], [MENU DOWN] buttons.
Select the response speed by pressing [DATA UP], [DATA DOWN] buttons.
The response speed becomes faster by pressing [DATA UP]
1 10 20
The response speed becomes slower by pressing [DATA DOWN]
(d) Changing the automatic shutter zone areaMove the “ ” to AREA by pressing [MENU UP], [MENU DOWN] buttons.
Select the measurement light area by pressing [DATA UP], [DATA DOWN] buttons.
䌛DATA UP䌝
PRESET A PRESET B PRESET C PRESET D PRESET E
䌛DATA DOWN䌝
The picture area is shown by the shaded area on the screen that is divided into 64 parts.
PRESET A | PRESET B | PRESET C | PRESET D |
PRESET E