Toshiba LQ500 specifications Installation, Outline Dimensions

Models: LQ500

1 9
Download 9 pages 8.7 Kb
Page 4
Image 4

LQ500

hours when programming every 5 minutes.

Moving average function:

In order to keep the average density (consistency) output, or in order to suppress the deflection width of the output. It helps for density (consistency) control.

<Specification>

Enable to determine a number from 1 to 99.

Change-rate limit function:

In order to reject the transient density (consistency) output as noises, or a sudden variation in the output according to intrusion by bubbles, etc....

<Specification>

Allowable rate of change limit: 0.00 to 9.99%TS Enable to determine a number from 0 to 99.

Additive correction function:

Available for up to 10 kinds of mixed / blended liquids. Sensitivity compensation can be set using registered parameters depending on the type and the mixing rate of liquids.

Password function:

This function is used to limit access to changing parameters that affect measured data by means of a password.

Arrestor:

Arrestors are installed in the LQ500 current output (4-20mAdc) and AC power lines.

Operation panel and Display:

Used to check data or change various settings. Operation switches: 5 switches.

Display: 4-line, 20-character LCD (dot-matrix) with backlight.

Power supply:

100 to 240Vac 50/60Hz (Allowable voltage: 85 to 264Vac)

Note: An additional power supply is required when choosing an optional environmental temperature specification type (-20 to 50 deg.C). Refer to the section of Environmental conditions in detail.

Note2: UL/CUL Hazardous locations type does not have a power switch. Please prepare a power switch outside. (Rated 250V AC,10A above, DPST: Double-Pole/Single-Throw)

Use the power switch for Hazardous locations in Hazardous locations area.

Power consumption: Approx. 25VA (100Vac), Approx. 35VA (240Vac)

Housing material: Steel plate

Coating: Polyurethane

MTBF: 135.8 months under 25 deg. C (77 deg. F) based on MLL-HDBK-217F

Installation

Outline Dimensions

250 (9.8”)

190 (7.5”)

Unit: mm

100 (3.9”)

(H)

 

 

 

(X)

 

 

(L)

 

 

 

 

Figure 3. LQ500 detector outline dimensions

 

 

 

 

Table 3. LQ500 detector outline dimensions

 

 

 

 

 

 

 

 

 

 

Size (mm)

X (mm)

H (mm)

L (mm)

 

 

Weight (kg)

 

DIN 16

 

ANSI 150

JIS 10K

 

 

 

 

 

 

50

(2”)

170 (6.7”)

225 (8.9”)

300 (11.8”)

Approx.22

 

Approx.21 (46 lb)

Approx. 21

80

(3”)

200 (7.9”)

225 (8.9”)

300 (11.8”)

Approx.30

 

Approx31 (68 lb)

Approx. 26

100 (4”)

220 (8.7”)

240 (9.4”)

300 (11.8”)

Approx.31

 

Approx.34 (75 lb)

Approx. 29

150 (6”)

270 (10.6”)

260 (10.2”)

300 (11.8”)

Approx.43

 

Approx.44 (97 lb)

Approx. 42

200 (8”)

320 (12.6”)

290 (11.4”)

300 (11.8”)

Approx.52

 

Approx.54 (119 lb)

Approx. 48

250

(10”)

300 (11.8”)

315 (12.4”)

350 (13.8”)

Approx.68

 

Approx.68 (150 lb)

Approx. 64

300

(12”)

360 (14.2”)

340 (13.4”)

350 (13.8”)

Approx.85

 

Approx.99 (218 lb)

Approx. 76

4

Page 4
Image 4
Toshiba LQ500 specifications Installation, Outline Dimensions