EO1-19036

LS-780 SERIES

• When the scanner cannot read a barcode...

Cause

Action

• The top window of the scanner is dirty or dewed.

• Clean the top window.

• Barcode system does not correspond to scanner

• Reading a barcode is unavailable. Use the barcode

specification.

system corresponding to the scanner specification.

• Barcode has a defect. (Print of a barcode is too

• Reading a barcode is unavailable.

light, dirty, blurred, or defaced.)

Read a perfect barcode attached to the same article.

 

Enter the barcode of the article manually by the

 

keyboard.

 

(However, depending on the function of the host

 

terminal.)

• Angle to read a barcode is not appropriate.

• Read the barcode at the appropriate angle. (Refer to

 

page 5 in details.)

• Barcode to be read is too near to the top window

• Read the barcode in the effective scanning zone.

or too far from the top window.

(Refer to pages 4 and 5.)

When a trouble still exists after taking the actions described above, ask your TOSHIBA TEC representative.

When the scanned data is not transferred to the host terminal...

Cause

Action

• The connector of the interface cable has been de-

• Attach the connector securely.

tached.

 

When a trouble still exists after taking the action described above, ask your TOSHIBA TEC representative.

8.SPECIFICATIONS

8.1Scanner Main Body

Dimensions:

200 (W) x 90 (D) x 220 (H) mm (Vertical standing dimensions)

Weight:

1.5 kg

Readable code:

EAN/JAN-13, EAN/JAN-8, UPC-A, UPC-E, EAN128,

 

EAN-13/8 and UPC-A/E with Supplemental 2 or 5 digits,

 

ITF (Interleaved 2 of 5), NW7 (CODABAR),

 

CODE39, CODE93, CODE128

Interface:

OCIA

 

RS-232C

 

USB

Reading Height:

Up to 200 mm above from the Scanner Window surface

Input Power:

12 VDC 10%

8.2Interface Cable (Option)

Cable Length:

5.0 m

- 8 -