9. ENVIRONMENTAL LIMITS

9.1 Temperature and Humidity

9.1.1 Temperature

 

 

 

 

 

Operating

5oC- 60oC

 

 

Gradient 15oC / Hour maximum

 

Non- operating

- 20oC- 65oC

 

 

Gradient 15oC / Hour maximum

 

Under shipment

- 40oC- 70oC

 

 

Gradient 30oC / Hour maximum

 

 

( Packed in Toshiba’s original shipping package. )

The temperature of top cover and base must be kept under 65at any moment to maintain the desire reliability.

9.1.2 Humidity

Operating

8%- 90%

R.H. ( No condensation. )

Non- operating

8%- 90%

R.H. ( No condensation. )

Under shipment

5%- 90%

R.H. ( Packed in Toshiba’s original shipping package. )

Max. wet bulb

29oC (Operating)

 

40oC (Non- operating)

9.2 Vibration

Operating

4 mm p-p displacement.

 

5-15 Hz

 

No unrecoverable error.

 

19.6 m/s2 ( 2.0G )

 

15- 500 Hz

 

Sine wave sweeping 1 oct./ minute

 

No unrecoverable error.

Non operating

10 mm p-p displacement.

 

5-15 Hz

 

No unrecoverable error.

 

49 m/s2 ( 5.0G )

 

15- 500 Hz

 

Sine wave sweeping 1 oct./ minute

 

No unrecoverable error.

9.3 Shock

 

Operating

4,900 m/s2 ( 500G )

 

 

 

2 msec half sine wave

 

 

 

Repeated twice maximum / second

 

 

 

No unrecoverable error.

 

 

Non- operating

14,700 m/s2 ( 1500G ) 1 msec half sine wave

 

 

 

Repeated twice maximum / second

 

 

 

No unrecoverable error.

 

 

Under shipment

70 cm free drop

 

 

 

No unrecoverable error.

 

 

 

Apply shocks in each direction of the drive’s three

 

 

 

mutually perpendicular axes, one axis at a time.

 

 

 

( Packed in Toshiba’s original shipping package. )

 

 

 

 

 