Chapter 2 Troubleshooting Procedures
Procedure 3 Diagnostic Test Program Execution Check
The HDD test program is stored in the Diagnostics Disk. Perform all of the HDD tests in the
Hard Disk Drive Test. Refer to Chapter 3, Tests and Diagnostics, for more information about
the HDD test program.
If an error is detected during the HDD test, an error code and status will be displayed. The
error codes and statuses are described in Table 2-5-1. If an error code is not displayed but the
problem still occurs, go to Procedure 5.
Code Status
01 Bad Command Error
02 Bad Address Mark Error
04 Record Not Found
05 HDC Not Reset Error
07 Drive Not Initialized
09 DMA Boundary Error
0A Bad Sector
0B Bad Track Error
10 ECC Error
11 ECC Recover Enabled
20 HDC Error
40 Seek Error
80 Time Out Error
AA Drive Not Ready
BB Undefined Error
CC Write Fault
E0 Status Error
F0 No Sense Error
?? Other Error
Table 2-5-1 HDD error code & status
Satellite T110D / Satellite Pro T110D / PORTEGE T110D Maintenance Manual (960-Q08)

1
6