8-9. Auto Restart Function
The indoor unit is equipped with an automatic restarting function which allows the unit to restart operating with the set operating conditions in the event of power supply being accidentally shut down. The operation will resume without warning three minutes after power is restored.
This function is not set to work when shipped from the factory. Therefore it is necessary to set it to work.
When the unit is on standby (Not operating)
8-9-1. How to set auto restart function
To set the auto restart function, proceed as follows: The power supply to the unit must be on; the function will not set if the power is off.
Push the [TEMPORARY] button located in the center of the front panel continuously for three seconds. The unit receives the signal and beeps three times. The unit then restarts operating automatically in the event of power supply being accidentally shut down.
Operation
Push [TEMPORARY] button for more than three seconds.
|
| 0 |
Hi POWER FILTER PRE.D | 3S | |
|
|
|
TEMPORARY button
When the unit is in operation
Operation
Push [TEMPORARY] button for more than three seconds.
|
| 0 |
Hi POWER FILTER PRE.D | 3S | |
|
|
|
TEMPORARY button
|
| Motions |
The unit is on standby. |
| |
→ |
|
|
The unit starts to operate. | The green lamp is on. | |
→ | After approx. three seconds, | |
The unit beeps three times | The lamp changes from | |
and continues to operate. | green to orange. |
If the unit is not required to operate at this time, push [TEMPORARY] button once more or use the remote control to turn it off.
|
| Motions |
The unit is in operation. | The green lamp is on. | |
→ |
|
|
The unit stops operating. | The green lamp is turned off. | |
→ | After approx. three seconds, |
The unit beeps three times.
If the unit is required to operate at this time, push [TEMPORARY] button once more or use the remote control to turn it on.
• | While this function is being set, if the unit is in | • | While the filter check lamp is on, the |
• | operation, the orange lamp is on. |
| TEMPORARY button has the function of filter |
This function can not be set if the timer operation |
| reset button. | |
| has been selected. |
|
|
•When the unit is turned on by this function, the louver will not swing even though it was swinging automatically before shutting down.