FILE NO. SVM-06012

8-9-2. How to cancel auto restart function

To cancel auto restart function, proceed as follows: Repeat the setting prodedure: the unit receives the signal and beeps three times.

The unit will be required to be turned on with the remote control after the main power supply is turned off.

When the unit is on standby (Not operating)

Operation

Push [TEMPORARY] button for more than three seconds.

 

 

0

Hi POWER FILTER PRE.D

3S

 

 

 

TEMPORARY button

 

 

Motions

The unit is on standby.

 

 

 

The unit starts to operate.

The orange lamp is on.

After approx. three seconds,

The unit beeps three times

The lamp changes from

and continues to operate.

orange to green.

If the unit is not required to operate at this time, push [TEMPORARY] button once more or use the remote control to turn it off.

When the unit is in operation

Operation

Push [TEMPORARY] button for more than three seconds.

 

 

0

Hi POWER FILTER PRE.D

3S

 

 

 

TEMPORARY button

 

 

Motions

The unit is in operation.

The orange lamp is on.

 

 

The unit stops operating.

The orange lamp is turned off.

After approx. three seconds,

The unit beeps three times.

If the unit is required to operate at this time, push [TEMPORARY] button once more or use the remote control to turn it on.

While this function is being set, if the unit is in operation, the orange lamp is on.

8-9-3. Power failure during timer operation

When the unit is in Timer operation, if it is turned off because of power failure, the timer operation is cancelled. Therefore, set the timer operation again.

8-10. Filter Check Lamp

When the elapsed time reaches 1000 hours, the filter check lamp indicates. After cleaning the filters, turn off the filter check lamp.

8-10-1. How to turn off filter check lamp

(1)Press [FILTER] button on the remote control.

(2)Push [TEMPORARY] button on the indoor unit.

Note:

If [TEMPORARY] button is pushed while the filter check lamp is not indicating, the indoor unit will start the Automatic Operation.

– 20 –

Page 22
Image 22