INSTALLATION-WIRING DIAGRAMS
SECTION lOO-816-208
MARCH1993
TO BASE UNIT (P5)
W/FEMALE CONNECTOR ;;;;2’NG STATION CABLING
Tl (VOICE/DATA)
(GND) RI (VOICE/DATA)
JACKETED TWISTED PAIRS
24AWG (1 OR 2 PAIR, SEE NOTE 2)
BR-W 1 4 E
CIRCUIT 2 TO DKT2
OR PDIU-DS Tl
1 ‘W
1 PT3 CIRCUIT 3 TO DKT3
I OR PDIU-DS “‘l,W-t-i-t , BLXI
1 in4
CIRCUIT 4 TO DKT4
1 ,PT4 OR PDIU-DS
- DPA
LII
R-GN 1 33 m
I r-1 I ,9 \\
GND (-) GND (-)
PR T R PT
FE& 1
CIRCUIT 5 TO DKT5
OR PDIU-DS
I PR5 OR DDCB
LAzA Pf6
E 1 PR6
CIRCUIT 6 TO DKT6
OR PDIU-DS
^. .ELEPHONE (DKT 1)
(SEE
NOTE 7’
~GN-BKI 13
CIRCUIT 7 TO DKT7
/ OR PDIu-DS

i

u

z

N”

r

66M150 SPLIT BLOCK
NOTES: 1. Voltage levels: T, PT = -26.3 - 27.8 VDC R, PR = 0.0 VDC (GND) (Reference to FG ground) 2. T/R wires are a/ways required; PT/PR are long station runs per Table 8-D. PT/PR m, 3. Standard Telephone circuits 7 - 4 require L----------, I I
RELAY CONTACT I ;/ .; I
1
NOT USED
1
STD CIRCUIT TEL 1
1
NOT USED
1
STD CIRCUIT TEL 2
1
NOT USED
1
STD TEL
CIRCUIT 3
1
NOT USED
1
STD TEL CIRCUIT 4
OR OPTIONAL BGM
SOURCE

\ C-J

PT
654321
PR T R
DDSS/BLF CONSOLE
(CIRCUIT 8 ONLY)
-OR-
DIGITAL
TELEPHONE (DKT 8)
-OR-
Nd only for runs also.
PDIU-DS
a ldditional power wires require 3 I be used with normal station a KSTU in the base unit.
FIGURE 8-8
DK16 MDF WIRING/BASE UNIT P5 AMPHENOL STATION AND RELAY CONNECTIONS
8-12