Trane 4TWA3 Installer’s Guide, Mounting Hole Location, Checkout Procedure, For model base size

Models: 4TWA3

1 8
Download 8 pages 62.66 Kb
Page 8
Image 8
MOUNTING HOLE LOCATION

Installer’s Guide

MOUNTING HOLE LOCATION

NOTE: ALL DIMENSIONS ARE IN MM (INCHES).

NOTE:

For model base size,

see table on page 7.

From Dwg. 21D152989 Rev. 0

CHECKOUT PROCEDURE

After installation has been completed, it is recommended that the entire system be checked against the following list:

1.

Refrigerant Line, Leak checked

[

]

2.

Suction Lines and Fittings properly insulated

[

]

3.

Have all Refrigerant Lines been secured and

 

 

 

isolated properly?

[

]

4.Have passages through masonry been sealed? If mortar is used, prevent mortar from coming

 

into direct contact with copper tubing

[

]

5.

Verify tightness of all electrical connects

[

]

6.

Observe outdoor fan during on cycle for clearance

 

 

 

and smooth operation

[

]

7.

Indoor coil drain line drains freely. Pour water

 

 

 

into drain pan

[

]

8.

Supply registers and return grilles open and

 

 

 

unobstructed

[

]

9.

Return air filter installed

[

]

10.

Thermostat thermometer is accurate. Check

 

 

 

against a reliable thermometer. Adjust per

 

 

 

instructions with thermostat

[

]

11.

Is correct speed tap being used?

 

 

 

(Indoor blower motor)

[

]

12.

Operate complete system in each mode to

 

 

 

insure safe operation

[

]

Trane

 

 

 

 

A business of

Trane has a policy of continuous product and product data improvement and it reserves the right to change

American Standard Companies

www.trane.com

design and specifications without notice.

18-BC62D1-1

P.I. 9/06

Page 8
Image 8
Trane 4TWA3 manual Installer’s Guide, Mounting Hole Location, Checkout Procedure, For model base size, see table on page