Manuals
/
Trane
/
Household Appliance
/
Water Pump
Trane
manual Model CVGF, Centrifugal Water Chillers, CTV-PRC001-E4, October
Models:
CVGF
1
1
28
28
Download
28 pages
34 b
1
2
3
4
5
6
7
8
<
>
Install
Dimension
Chilled-WaterReset
Shipment and Assembly
Phase-UnbalanceProtection
Weight
Features and Benefits
Page 1
Image 1
Centrifugal
Water Chillers
Model CVGF
Water-Cooled
Hermetic Centrifugal Refrigeration Capacities from
400 to 1000 Tons (1400
~
3510 kW)
50 and 60 Hz
October 2008
CTV-PRC001-E4
Page 2
Page 1
Image 1
Page 2
Contents
Centrifugal Water Chillers
Model CVGF
CTV-PRC001-E4
400 to 1000 Tons 1400~3510 kW 50 and 60 Hz
Introduction
Introduction
Contents
Optional Features
Features and Benefits
Applications
Patents
Advanced Heat Transfer Surfaces
Simple Installation
Compact Size
Improved Efficiency
Tracer AdaptiViewTM Control Operator Interface
Features and Benefits
Features and Benefits Tracer TU Interface
Tracer AdaptiViewTM Controller
Features and Benefits
Building Automation and Chiller Plant Control
Feedforward Adaptive Control
Integrated Comfort System ICS
Chiller-TowerOptimization
Why Centrifugal Compressors Surge
Features and Benefits
Two-StageCompressor Widens the Application Range
Two-StageCompressors Surge Less and Later
Condenser Water Limitations
Application Considerations
Temperature
Water Pumps
Water Treatment
Application Considerations
Table GD-2- Weight
General Data
Table GD-1- Model CVGF Description
50 and 60 Hz SI Units and English Units
General Data
Supply and Motor Lead Wiring and Connections
Jobsite Connections
Shipment and Assembly
Standard Features
Controls
Phase Voltage Sensors - 3 phase
Chilled-WaterReset
Controls
Optional Features
Extended Operation Package
Base-LoadingControl
High Condenser-PressureProtection
Standard Protections
Starter-ContactorFailure Protection
Loss of Water-FlowProtection
Phase-LossProtection
Phase-UnbalanceProtection
Phase Reversal/Rotation Protection
Standard Protections
Standard Protections
Power Factor and kW Measurement
Current Overload Protection
High Motor-WindingTemperature Protection
Short-CyclingProtection
Standard Protections
Dimensions - SI Units English Units
Physical Dimensions
50 and 60 Hz SI English Units
Figure PD-1 -ModelCVGF Cooling Only
Model CVGF Water Connection Pipe Size
Physical Dimensions
Evaporator Water Box Length - SI I-P
Condenser Water Box Length - SI I-P
Compressor
Mechanical Specifications
Drive Train
Motor
Condenser
Mechanical Specifications
Unit Control Panel
Isolation Pads
Compressor-MotorStarter
Refrigerant and Oil Charge
Painting
CTV-PRC001-E4
Conversion Table
CTV-PRC001-E4
Literature Order Number
Date
October