Trane GAF2A0A24S21SA Model, Dim A, Electrical Data, Blower Housing Wheel, Belly Band A Motor

Models: GAF2A0A36S31SA GAF2A0A30S21SA GAF2A0A24S21SA

1 20
Download 20 pages 34.54 Kb
Page 12
Image 12
BLOWER HOUSING

Electrical

Data

WIRING DATA

GAF2A0A36S31SA

 

 

 

 

240 VOLT

 

 

 

208 VOLT

 

Heater

No.

 

 

 

 

 

 

 

 

 

 

 

 

Heater

 

 

 

 

Heater

 

 

Model

of

Capacity

Minimum

Maximum

Capacity

Minimum

Maximum

Amps

Amps

No.

Circuits

 

 

Circuit

Overload

 

 

Circuit

Overload

 

 

per

 

 

per

 

 

kW

BTUH

Ampacity

Protection

kW

BTUH

Ampacity

Protection

 

 

Circuit

Circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Heater

-

-

-

2.4**

3

15

-

-

2.4**

3

15

 

 

 

 

 

 

 

 

 

 

 

 

BAYECAA05++

1

4.80

16400

20

28

30

3.60

12300

17.3

25

25

 

 

 

 

 

 

 

 

 

 

 

 

BAYECAA08++

1

7.68

26200

32

43

45

5.76

19700

27.7

38

40

 

 

 

 

 

 

 

 

 

 

 

 

BAYECAA10++

1

9.60

32800

40

53

60

7.20

24600

34.6

46

50

 

 

 

 

 

 

 

 

 

 

 

 

Note: ** Motor Amps

DISTANCE FROM BELLY BAND TO SHAFT FACE OF MOTOR FOR MINIMUM VIBRATION

BLOWER HOUSING

WHEEL

BELLY BAND

A

MOTOR

A is determined per chart

Wheel is centered in

Blower Housing

MODEL

DIM "A"

GAF2A0A18S11SA

1-1/8

 

 

GAF2A0A24S21SA

2-11/16

 

 

GAF2A0A30S21SA

1-9/16

 

 

GAF2A0A36S31SA

1-11/16

 

 

12

Pub. No. 22-1858-02

Page 12
Image 12