Heater Attribute Data

TAM7A0A24H21SB

 

 

 

 

 

 

 

240 Volt

 

 

 

 

 

 

 

 

 

208 Volt

 

 

 

 

 

Heater Model No.

 

No. of

 

Capacity

Heater

Minimum

 

Maximum

 

Capacity

 

Heater

Minimum

 

Maximum

 

 

Circuits

 

 

 

 

Amps per

Circuit

 

Overload

 

 

 

 

 

 

Amps per

 

Circuit

 

Overload

 

 

 

 

 

kW

 

BTUH

Circuit

Ampacity

 

Protection

 

kW

 

 

BTUH

 

Circuit

Ampacity

 

Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Heater

0

-

-

3.0**

4

15

-

 

-

3.0**

4

 

15

 

BAYEVAC05++1

1

4.80

16400

20.0

29

30

3.60

 

12300

17.3

25

 

25

 

BAYEVAC08++1

1

7.68

26200

32.0

44

45

5.76

 

19700

27.7

38

 

40

 

BAYEVAC10++1 1

1

9.60

32800

40.0

54

60

7.20

 

24600

34.6

47

 

50

 

BAYEVAC10LG3

 

1-3 PH

9.60

32800

23.1

32

35

7.20

 

24600

20.0

28

 

30

 

Note: ** Motor Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Heater not qualified for 208V when installed in horizontal left position without Heat Pump.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heater Attribute Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TAM7A0B30H21SB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240 Volt

 

 

 

 

 

 

 

 

 

208 Volt

 

 

 

 

 

Heater Model No.

 

No. of

 

Capacity

Heater

Minimum

 

Maximum

 

 

Capacity

 

Heater

 

Minimum

Maximum

 

 

Circuits

 

 

 

 

Amps per

Circuit

 

Overload

 

 

 

 

 

 

Amps per

 

Circuit

Overload

 

 

 

 

 

kW

 

BTUH

Circuit

Ampacity

Protection

 

kW

 

 

BTUH

 

Circuit

 

Ampacity

Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No Heater

 

0

 

-

 

-

3.0**

4

 

15

 

-

 

 

-

 

3.0**

 

4

 

15

 

BAYEVAC05++1

 

1

 

4.80

 

16400

20.0

29

 

30

 

3.60

 

 

12300

 

17.3

 

25

 

25

 

BAYEVAC08++1

 

1

 

7.68

 

26200

32.0

44

 

45

 

5.76

 

 

19700

 

27.7

 

38

 

40

 

BAYEVAC10++1

 

1

 

9.60

 

32800

40.0

54

 

60

 

7.20

 

 

24600

 

34.6

 

47

 

50

 

BAYEVAC10LG3

 

1-3 PH

 

9.60

 

32800

23.1

32

 

35

 

7.20

 

 

24600

 

20.0

 

28

 

30

 

BAYEVBC15LG3

 

1-3 PH

 

14.40

 

42000

34.6

47

 

50

 

10.80

 

 

36900

 

30.0

 

41

 

45

 

BAYEVBC15BK1 - Circuit 1 1

 

2

 

9.60

 

32800

40.0

54

 

60

 

7.20

 

 

24600

 

34.6

 

47

 

50

 

BAYEVBC15BK1 - Circuit 2

 

 

 

4.80

 

16400

20.0

25

 

25

 

3.60

 

 

12300

 

17.3

 

22

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: ** Motor Amps

1 MCA and MOP for circuit 1 contains the motor amps

Notes:

1. See Air Handler nameplate for approved combinations of Air Handlers and Heaters

2. Heater model numbers may have additional suffix digits.

Pub. No. 22-1847-03

13

Page 13
Image 13
Trane TAM7A0C48H41SB, TAM7A0C60H51SB, TAM7B0C60H51SA, TAM7A0C42H31SB, TAM7A0C36H31SB, TAM7A0B30H21SB manual Electrical Data