Field

Field

Wiring

Single Stage Cooling

Air Conditioner

Neatly bundle all low voltage wires behind the service valve cover as shown.

Comfort Control

WWhite

G

GreenY1

O

Yellow

R

B

Red

Y2

 

Blue

 

Field wiring

Air Handler

W3 *

 

W2

Blue

W1

 

BK

Yellow

G

 

Y2

 

YI (In)

 

O

 

R

B - Blue

B

YO (Out)

Y1 - Yellow

•• * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat.

•• YI and YO connections must be made as shown for freeze protection and internally mounted condensate overflow circuits to work properly.

•• Internally mounted condensate switch is optional and must be ordered separately.

•• If 3rd party condensate overflow switches are installed, they should be wired in series between YO and Y to the outdoor unit.

20