Trane TAM7A0C36H31SB, TAM7A0C60H51SB, TAM7A0C48H41SB manual Field Wiring, Two Stage Cooling

Models: TAM7A0C36H31SB TAM7A0C42H31SB TAM7A0C48H41SB TAM7B0C60H51SA TAM7A0B30H21SB TAM7A0C60H51SB

1 28
Download 28 pages 33.03 Kb
Page 22
Image 22
Two Stage Cooling

Field

Wiring

Two Stage Cooling

Air Conditioner

Neatly bundle all low voltage wires behind the service valve cover as shown.

Comfort Control

 

W

White

G

Green

Y1

Yellow

O

Red

R

B

Blue

Y2

Brown

Field wiring

 

Air Handler

 

Yellow/Black

W3 *

Yellow/Red

W2

 

W1

Blue

BK

G

 

Y2

Y2 - Brown

YI (In)

 

O

 

R

B - Blue

B

YO (Out)

Y1 - Yellow

•• * For multiple stages of electric heat, jumper W1, W2, and W3 together if comfort control has only one stage of heat.

•• YI and YO connections must be made as shown for freeze protection and internally mounted condensate overflow circuits to work properly.

•• Internally mounted condensate switch is optional and must be ordered separately.

•• If 3rd party condensate overflow switches are installed, they should be wired in series between YO and Y to the outdoor unit.