Transition Networks CPSMC0800-100 manual Installing the Managment Modules

Models: CPSMC0800-100

1 26
Download 26 pages 56.08 Kb
Page 10
Image 10

CPSMC0800-100 PointSystem™ Chassis

2.2.2Installing the Managment Modules

CAUTION: Wear a grounding device and observe electrostatic discharge precau- tions when installing the Management Module(s) in the 8-Slot chassis. Failure to observe this caution could result in damage to, and subsequent failure of, the Management Module.

Install one (1) Master Management Module (CPSMM-120 or CPSMM-200) in the primary managed CPSMC0800-100 8-Slot chassis.

If several PointSystem™chassis are to be connected in a cascade fashion (see sec- tion 4.3 Cascade Option):

Install one (1) Master Management Module (CPSMM-120 or CPSMM-200) into the primary managed CPSMC0800-100 8-Slot chassis.

Install one (1) Master Management Module (CPSMM-200) or one (1) Expansion Management Module (CPSMM-210) in any secondary managed CPSMC0800- 100 8-Slot chassis.

NOTE: Though the Management Module(s) can be installed in any PointSystem™ chassis slot, use of the left-most installation slot(s) for installing the Management Module(s) is recommended in order to keep the cascading cables separate from the network cables connected to the installed on Media Converter Slide-In-Modules.

To install a Management Module:

1a. CPSMM-200 Dual-Slot Master Management Module:

Remove two (2) Management Module protective plates from two (2) installation slots at the far-left position by removing the one (1) screw that secures each pro- tective plate to the PointSystem™ chassis.

1b. CPSMM-120 Single-Slot Master Management Module OR

CPSMM-210 Single-Slot Expansion Management Module:

Remove one (1) Management Module protective plate from one (1) installation slot at the far-left position by removing the one (1) screw that secures the pro- tective plate to the PointSystem™ chassis.

2.Align the Management Module with the PointSystem™ chassis installation slot so that the panel fastener screw is to the left of the Management Module.

 

 

 

 

 

 

 

Input Power:

 

 

 

 

 

 

 

110-240 VAC

 

 

 

 

 

 

 

1.6A max. (60W max)

 

 

 

 

 

 

 

50/60 Hz

 

 

RESET

DB-9

 

 

 

PWR

LNK

 

 

 

 

CPSMC-0800

TX

RX

 

 

 

 

 

8-Slot Chassis

 

 

TERM

INIT

12C

12C-1

 

MGMT MASTER

 

10BASE-T

INPORT

OUTPORT

MCCM10

Panel Fastener Screw

3.Carefully slide the Management Module into the installation slot, aligning the Management Module with the installation guides.

NOTE: Ensure that Management Module is firmly seated against backplane.

4.Rotate the attached panel fastener screw clockwise to secure the Management

Module to the PointSystem™ chassis.

slide-in-modules

Tech Support: 7am-6pm CST (GMT -6:00)1-800-260-1312 International: 00-1-952-941-7600