SCSCF30xx-10x

6.Is Data Transfer Failing?

YES

Verify the local copper connection by starting a local copper loop-back (set the loop-back switch on the local Device to “CL”) and then use a bit error test unit at the local location to run a bit error test.

ErrorBit

UnitTest

Copper

Local

Fiber

Remote

Copper

Remote

Device

 

 

 

 

 

 

Converter

Converter

 

 

 

 

 

 

 

 

 

Verify the local fiber connection by starting a local fiber loop-back at the remote location (set the loop-back switch on the remote Device to “FL”) and then use a bit error test unit at the local location to run a bit error test.

BitE rror

Test Unit

 

Local

 

Remote

Local

Device

 

 

Copper

Converter

Fiber

Converter

Copper

 

 

 

 

 

 

 

Verify the remote copper connection by starting a local copper loop-back at the remote location (set the loop-back switch on the remote Device to “CL”) and then use a bit error test unit at the remote location to run a bit error test.

BitE rror

Test Unit

 

Local

 

Remote

Local

Device

 

 

Copper

Converter

Fiber

Converter

Copper

 

 

 

 

 

 

 

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

Proceed to step 7.

7.Is the SDC (Signal Detect / Coax) LED illuminated yellow?

YES

A failure of the remote unit connected to the coax interface has caused an Alarm Indication Signal (AIS) on the coax interface. Correct the remote unit failure.

 

AIS on coax link

 

Coax

Fiber

Coax

 

Original Fault

 

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

Proceed to step 8.

8.Is the SDF (Signal Detect / Fiber) LED illuminated yellow?

YES

A broken coax link has caused an Alarm Indication Signal (AIS) on the fiber interface. Correct the coax link failure.

Original

 

AIS on fiber link

Fault

 

 

Coax

Fiber

Coax

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

Declaration of Conformity

Name of Mfg: Transition Networks

10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.

Model:

SCSCF30xx-10x Series Device

Part Number:

SCSCF3011-100, SCSCF3013-100, SCSCF3014-100,

SCSCF3015-100, SCSCF3016-100, SCSCF3017-100,

SCSCF3018-100, SCSCF3019-100, SCSCF3029-100,

SCSCF3029-101, SCSCF3029-102, SCSCF3029-103,

SCSCF3039-100

Regulation:

EMC Directive 89/336/EEC

Purpose: To declare that the SCSCF30xx-10x to which this declaration refers is in conformity with the following standards.

EN 55022:1998 Class A; EN 55024:1998; FCC Part 15 Subpart B; CFR 21 subpart J 61000-3-2:1995+A14:2000; 61000-3-3:1995;

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

February, 2009

Stephen Anderson, Vice-President of Engineering

Date

10

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

11

Page 6
Image 6
Transition Networks SCSCF30XX-10X specifications Declaration of Conformity, Name of Mfg Transition Networks