Transition Networks SSDTF1013-105 Technical Specifications, Troubleshooting, SSDTF10xx-10x

Models: SSDTF1018-105 SSDTF1012-105 SSDTF1025-105 SSDTF1011-105 SSDTF1027 SSDTF1013-105 SSDTF1014-105 SSDTF1029-105 SSDTF1027-105 SSDTF1022-105 SSDTF1029-108 SSDTF1029-106 SSDTF1029-107

1 9
Download 9 pages 10.6 Kb
Page 7
Image 7
Technical Specifications

SSDTF10xx-10x

Technical Specifications

For use with Transition Networks Model SSDTF10xx-10x or equivalent

Standards:

Emissions: CISPR A; Telecordia TR-NWT-001089

 

(designed to meet; NOT tested); FCC Part 68; T1/E1

 

Physical layer: ITU-T, ANSI, AT&T, and ETSI; European

 

Technical Standard: TBR 12; British Technical

 

Publication: PD 7024 : 1994 (NTR 4)

Dimensions:

3.25" x 4.7" x 1" (83 mm x 119 mm x 25 mm)

Weight:

10 oz. (283 g) approximately

Power consumption:

3.7 Watts

Power supply:

12VDC, 0.8A (North America, Europe, UK)

 

12VDC, 1.25A (NZ, Australia, S Africa, JP, Latin Am)

 

(The external power supply provided with this product

 

is UL listed by the power supply’s manufacturer.)

MTBF:

47,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)

 

116,000 hours (Bellcore7 V5.0)

Environment:

0°C to 50°C (32°F to 122° F )

Storage Temp:

-15°C to 65°C (5°F to 149°F)

Humidity:

10 to 90%, non condensing

Altitude:

0 to 10,000 feet

Warranty:

Lifetime

The information in this user’s guide is subject to change. For the most up-to-date information on the SSDTF10xx-10x Device, view the user’s guide on-line at: www.transition.com.

Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.

CAUTION: Visible and invisible laser radiation when open. Do not stare into the beam or view directly with optical instruments.

CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.

Troubleshooting

If the device fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:

1.Is the PWR (Power) LED illuminated?

NO

Is the power adapter the proper type of voltage and cycle frequency for the AC outlet? (See “Technical Specifications” on page 12.)

Is the power adapter properly installed in the device and in the outlet?

Does the grounded AC outlet provide power?

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 2.

2.Is the SDC (Signal Detect/Copper) LED illuminated?

NO

Check the twisted-pair copper cable for the proper connection.

Check the MDI/MDI-X switch for the correct twisted-pair copper cable configuration (see page 3).

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 3.

3.Is the SDF (Signal Detect/Fiber) LED illuminated?

NO

Check the fiber cables for proper connection.

Verify that the TX and RX cables on the local device are connected to the RX and TX ports, respectively, on the remote device.

Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 4.

12

13

Page 7
Image 7
Transition Networks SSDTF1013-105 Technical Specifications, Troubleshooting, Is the PWR Power LED illuminated? NO