SIBTF10xx-1xx-Mx

Technical Specifications

For use with Transition Networks Model SIBTF10xx-1xx-Mx or equivalent.

Standards:

IEEE 802.3™ 2000, IEEE 802.3x™

Data Rate:

10 Mb/s, 100 Mb/s (copper), 100 Mb/s (fiber)

Dimensions:

Models 130- & 140-Mx

 

(W x H x D) 4.125" x 6" x 5" (104.77 x 152.4 x 127 mm)

Dimensions:

Model 110-Mx

 

(W x H x D) 3.375" x 6" x 5" (85.73x 152.4 x 127 mm)

Weight:

3.2 lb. (1.5 kg) approximately

Input Voltage:

48170VDC +/-15%

 

90125VAC +/-15%, 50/60 Hz

Power:

15 W (maximum)

 

Aux input standby power, 200 mW typically

Fuse:

2.5 A/250 VDC

Alarm Relay:

Three-position screw terminal block for the dry contact relay

 

0.5 A @ 125 VAC / 2.0 A @ 30 VDC (maximum)

 

switching capacity: 60 W (maximum)

Packet Size:

Memory: 64K Bytes

 

Unicast MAC addresses: 1000

 

Maximum packet size: 1536 Bytes

MTBF*:

51,115 MIL-HDBK-217F Hours

 

153,038 Bellcore Hours

Environment

-40 to 75°C (-40 to 167°F)

Operating Temp:

Storage Temp:

-40 to 85°C (-40 to 185°F)

Humidity:

5 to 95%, non-condensing

Altitude:

3000 m (10,000 ft.)

Warranty:

Lifetime

The industrial switch is designed for installation in restricted access locations. Installing the industrial switch into other equipment or facility control rooms must comply with the fire-enclosure requirements of IEC60950/EN60950/UL60950, along with other local, national fire and safety codes.

IMPORTANT: Copper based media ports: e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc. are intended for connecting to intra-building (inside plant) link segments, not subject to lightening transients or power faults. Copper based media ports: e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422, RS485, DS1, DS3, Video Coax, etc. are NOT for connecting to inter- building (outside plant) link segments subject to lightening transients or power faults.

*MTBF is estimated using the predictability method. This method is based on MIL- 217F at 25°C ambient temperature, typical enclosure heat rise of 10°C, and nominal operating conditions and parameters. Installation and configuration specific MTBF estimates are available upon request. Contact Technical Support.

Technical Specification -- continued

220–240VAC, 50/60Hz installation

CAUTION: If the main power source is 220-240VAC @50/60Hz, use a 2:1, 50VA or greater step-down transformer between the main power source and the industrial switch. Failure to observe this caution could result in a damaged switch.

EMC Type Tests (all test were performed using unshielded cables)

Standard

Description

Compliance Level

Remarks

 

 

 

 

EN55022/FCC Part15

ITE Emissions

Class A

Conducted and radiated

 

 

 

 

EN55024/EN61000-6-2:

ITE Emissions

 

 

 

 

 

 

IEC61000-4-2

 

Level 2

ESD contact discharge

 

 

 

 

IEC61000-4-3

 

Level 4

Radiated fields

 

 

 

 

IEC61000-4-4

 

Level 3

Fast transients - power port

 

 

 

2 meter cable AC

 

 

 

1 meter cable DC

 

 

 

 

 

 

Level 2

Fast transient – Ethernet port

 

 

 

3 meter cable length

 

 

 

 

IEC6100-4-5

 

Level 3 CM

Surge – power port

 

 

Level 2 DM

2 meter cable AC

 

 

Level 1 DC

1 meter cable DC

 

 

 

 

 

 

Level 2

Surge – relay port

 

 

 

1 meter cable length

 

 

 

 

 

 

Level 2

Surge – Ethernet port

 

 

 

3 meter cable length

 

 

 

 

IEC61000-4-5

 

EN61000-6-2 Level 3

Conducted – power port

 

 

EN55024 Level 2

2 meter cable AC,

 

 

 

1 meter cable DC

 

 

 

 

 

 

EN61000-6-2 Level 3

Conducted – relay port

 

 

EN55024 Level 2

1 meter cable length

 

 

 

 

 

 

EN61000-6-2 Level 3

Conducted – PE Studs

 

 

EN55024 Level 2

2 meter cable length

 

 

 

 

 

 

EN61000-6-2 Level 3

Conducted – Ethernet port

 

 

EN55024 Level 2

10 meter cable length

 

 

 

 

IEC61000-4-8

 

Level 1

Power freq. mag. field

 

 

 

 

IEC61000-4-11

 

N/A

VoltageDIPs and variations

 

 

 

 

IEEE1613, Power Substation Testing

 

 

 

 

 

 

IEEE1613, Clause 6.2

 

Not rated

Dielectric power freq.

 

 

 

 

IEEE1613, Clause 6.3

 

Compliant

Impulse voltage all ports

 

 

 

 

IEEE1613, Clause 7.3.1

 

Class 2 transverse and

Surge oscillatory waveform

 

 

common Mode

–power AC

 

 

 

 

 

 

Class 2 transverse and

Surge oscillatory waveform

 

 

common Mode

–power DC

 

 

 

 

 

 

Class 2 common mode

Surge oscillatory waveform

 

 

 

–relay port

 

 

 

 

 

 

Class 2 common mode

Surge oscillatory waveform

 

 

 

–Ethernet 10 Mbps

 

 

 

 

 

 

Class 1 common mode

Surge oscillatory waveform

 

 

 

– Ethernet 100 Mbps

 

 

 

 

22

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

23

Page 12
Image 12
Transition Networks SUBTF10XX-1XX-MX specifications Technical Specifications, 220-240VAC, 50/60Hz installation