ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTIONS

Important

THIS COOKER MUST BE EARTHEDAny electrical work required to install this cooker should be carried out by a qualified electrician or competent person, in accordance with the current regulations.

Before connecting check that:THIS COOKER MUST BE EARTHED

How to proceed?The manufacturer declines any liability should these safety measures not be observed.

This cooker is designed to be connected to a 240V, 50Hz electrical supply.

To connect to the electricity supply, use cable type H05 RR-F.

Before connection, make sure the electricity supply voltage is the same as that indicated on the rating plate.

The cooker is supplied without supply cable. A 3 core flexible supply cord must be fitted, in accordance with the specification given in the table no.1.

The electrical connection should be made using a double pole isolating switch (cooker control switch) with at least 3mm contact separation in all poles. The cable must have conductors of sufficiently high cross-sectional area to prevent overheating or deterioration.

The switch should be sited within 2m of the cooker and be easily accessible at all times.

The yellow-green earth wire must not to be interrupted by the switch.

Manual background Ensure that the cooker supply cable does not come into contact with surfaces with temperatures higher than 50 °C.

Table no.1

Connection type

Single phase (UK)

 

 

 

 

 

 

 

 

4

5

 

 

 

 

 

Cable connection to the

1

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

terminal block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

N

 

PE

 

 

 

 

 

 

Mains Voltage

 

 

 

 

 

240 V

Voltage of heating

 

 

 

 

 

240 V

elements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse capacity

 

 

 

 

 

32 A

 

 

 

 

 

 

 

Cable section

 

 

 

 

3x6 mm2

NOTE: The earth wire should be about 2 cm longer than the live and neutral wires.

Before connecting check that:

The fuse and household electrical installation can carry the absorbed current of the appliance (see rating plate);

The cooker connection outlet or the cooker control switch is easily accessible when the appliance is installed.

How to proceed?

Unscrew and remove the protective cover at the back of the appliance;

Connect the power cable to the terminal block of the cooker according to the table no.1;

Secure by means of cable clamp;

Make sure that the connection to the terminal block is matching the supply system, see table no.1;

Refit and screw the protective cover on the back of the appliance.