Tricity Bendix SIG 233/1 installation instructions Gas Connections, Levelling

Models: SIG 233/1

1 28
Download 28 pages 12.83 Kb
Page 24
Image 24
Manual background

Levelling

The appliance is provided with adjustable small feet placed in the back and front corners of the base.

By adjusting the small feet it is possible to change the height of the appliance so as to ensure a better levelling with other surfaces and a uniform distribution of the liquids contained in pans or pots.

GAS CONNECTIONS

Gas connection must be carried out according to the rules in force.

Your cooker is delivered adjusted for the kind of gas stated on the rating plate.

If the appliance is converted to natural gas and the pressure for natural gas is 20mbar. The following methods of connection to the gas supply must be used:

Left Hand Connection (from front)

Ensure that the rubber hose and power cord are not in contact with any part of the hatched area shown in the diagram and that the loop of the hose when connected is not in contact with the floor when the appliance is in position.

Right Hand Connection (from front)

Ensure that the rubber hose and power cord are not in contact with any part of the hatched area shown in the diagram. It will be necessary to fit the maximum length hose when using this

method.

Rigid Connection

Where it is not possible to make the connection using a rubber hose, a rigid pipe work connection must be used.

Recommendations when using an appliance flexible connector are as follows:

-For NATURAL the gas installation pipes to the termination point shall comply with:

Specification for installation of low-pressure gas pipe work of up to 20mm (R1) in domestic premises (2nd family gas) – BS 6891; Connection shall be by means of an appliance flexible connector for use with a self-sealing plug- in device, complying with:

Flexible hoses, end fittings and sockets for gas burning appliances – BS 669;

22

connection Manual background of flexible

hose

power Manual background cord

connection of flexible hose

power

cord

Page 24
Image 24
Tricity Bendix SIG 233/1 installation instructions Gas Connections, Levelling