Tricity Bendix SIG 233/1 installation instructions Advice For Safety, Gas connections

Models: SIG 233/1

1 28
Download 28 pages 12.83 Kb
Page 19
Image 19
ADVICE FOR SAFETY

ADVICE FOR SAFETY

Gas connections

Before installation ensure that the local distribution conditions (gas type and pressure) and the pre-setting of the appliance are consistent.

This appliance must be installed only in a room with good ventilation.

This appliance must not connected to a chimney. It has to be installed and connected in accordance with the rules in force. Special attention should be paid to the applicable disposal concerning ventilation.

The adjacent furniture panels have to be heat proof or protected by such material.

The adjusting conditions of this appliance are mentioned on the rating plate.

Connection to gas supply.

Check that the gas flow and the diameter of the supply pipe is sufficient to supply all the appliances of the installation.

Check that all connections are tight.

Install an accessible and visible gas tap to isolate the appliance.

Gas connectionsThe manufacturer declines any responsibility for possible damages resulting from an installation, which doesn't comply with current legislation.

-Installation of flues and ventilation for gas appliances of rated input not exceeding 60 kW (1st, 2nd and 3rd family gases) – Part 2 Specification for installation of ventilation for gas appliances – BS 5440 Current editions;

-Gas burning appliances – Part 3 Domestic cooking appliances burning gas – BS 5386 Current editions;

-Specification for installation of low pressure gas pipe work of up to 20mm (R1) in domestic premises (2nd family gas) – BS 6891 Current editions;

-Pipe threads for tubes and fittings where pressure-tight joints are made on the threads (metric dimensions) – BS 21 Current editions;

-Flexible hoses, end fittings and sockets for gas burning appliances – BS 669 Current editions;

-Installation of domestic gas cooking appliances (1st, 2nd and 3rd family gases) –

BS 6172: 1990 Current editions;

-