SAFETY INSTRUCTIONS
PLEASE READ THE FOLLOWING SAFETY INSTRUCTIONS BEFORE INSTALLING AND OPERATING THE UNIT:
This air conditioner meets strict safety and operating standards. The installer of this unit must install or service this unit so it operates safely and efficiently.
IMPORTANT NOTES
•Adhere to all safety instructions and warnings through- out this manual.
•Read this manual carefully before installing or operating this unit to become familiar with its features and obtain the performance that will bring you continued enjoy- ment for many years.
•Follow each installation or repair step exactly as shown in the manual.
•Observe all local, state and national electric codes. Contact your local government for more information on electrical codes.
The lightning flash with arrowhead symbol, with- in an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral tri- angle is intended to alert the user to the pres- ence of important operating and maintenance (servicing) instructions in the literature accom- panying the appliance.
Contact Installer if Necessary:
The installation instructions are for a experienced in- staller. If you are not an experienced installer, contact a local installer for help. If you require help with service, contact your certified dealer or Daewoo Electronics for additional instructions.
If Unit is Installed Improperly:
The manufacturer shall in no way be responsible for im- proper installation or maintenance service, including fail- ure to follow the instructions in this manual.
WARNING:
•ELECTRICAL SHOCK CAN CAUSE SEVERE PER- SONAL INJURY OR DEATH. ONLY A QUALIFIED, EX- PERIENCED ELECTRICIAN/INSTALLER SHOULD AT- TEMPT TO WIRE THIS SYSTEM.
•THE APPLIANCE IS NOT INTENDED FOR USE BY CHILDREN OR INFIRM PERSONS WITHOUT SUPER- VISION
•YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT DO NOT PLAY WITH THE APPLIANCE
Precautions When Wiring:
•Do not plug in the unit until all connections (tubing, drain hose, mounting, etc.) have been made and dou-
•High voltages are present in this unit and are very dan- gerous. Please refer to these instructions and diagrams when wiring. Improper connections or inadequate grounding can cause accidental injury.
•This unit must be grounded in accordance with local electrical codes.
•Connect wires and pipes securely and tightly as loose connections/wiring may cause overheating at connec- tions and a possible fire hazard.
Precautions When Transporting:
•When transporting the unit, be very careful and get help as the units are very heavy. Be careful of sharp edges on the units also.
Precautions When Installing:
•When installing in a ceiling or wall, make sure the ceiling/wall is strong enough to hold the unit’s weight. A frame may be necessary for added support.
•When installing in a room, make sure the tubes are well insulated to protect the walls and furniture from sweating of the tubes.
•When installing in moist or uneven locations, make sure to use a raised level concrete pad or concrete blocks to provide a level, solid foundation for the out- door unit; this prevents water damage and vibration.
•When installing in an area of high winds, make sure to securely anchor the outdoor unit down with bolts and a metal frame.
When Connecting Refrigerant Tubing:
•Keep all tubing as short as possible.
•Use the flare method for connecting tubing.
•Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten , making sure not to overtighten.
•Check the tubes carefully for leaks before starting the test run.
When Servicing:
•Make sure the power is off and the unit is unplugged before opening the unit to troubleshoot or repair electri- cal parts and wiring.
•Keep your fingers and clothing away from any moving parts.
•Clean up the sight after you finish, making sure no met- al scraps and wiring are left in the unit.
•The Air conditioner shall be installed in accordance with the nat ioned wiring regulation.
1