Daewoo DSB-071LH, Split Airconditioning System owner manual Installation Diagram, Overview, Notes

Models: DSB-071LH Split Airconditioning System

1 30
Download 30 pages 52.43 Kb
Page 6
Image 6
INSTALLATION DIAGRAM

INSTALLATION DIAGRAM

Below is an overview for the connection of the the Indoor unit to the Outdoor unit. The pages following will give detailed instructions for full installation. Remember to read the complete Installation section and follow all the safety instructions fully when installing the Indoor and Outdoor units.

OVERVIEW

This appliance must be installed according to national power supply aequirement.

10cm (3.95in) from ceiling

10cm (3.95in) from

side wall

30cm (11.8in) from

side wall

At least 30cm (11.8in) from unit

AC Outlet

and Plug

Plug into 220V

AC Outlet

23.6

60

cm

inches

 

 

Wall

 

Wall

Drain

 

Bracket

Hose

Wall Cap

 

 

Pipes

(Not Supplied)

AC

Connection

(Not Supplied)

Wrap with

Tape

Maximum Height 7M(21Ft)

Maximum Length 15M(49Ft)

Any tube length between 7 and 15 meters must

be precharged with freon using the following calulation:

(Length – 5) x 30 grams

Adding additonal tubing will decrease efficiency

10 cm

3.9 inches

NOTES:

After installation it must be possi- ble for the user to disconnect the power supply plug.

If the AC outlet is a 3-pronged type or other, have an electrician install a new outlet.

Contanct service man when re- place the power cord set.

The specification of AC connection is 1.5mm2X5PX6m.

 

 

27.6

 

 

 

70

inches

 

 

cm

 

 

 

 

 

Copper

Drain

 

 

 

Tubing

 

 

 

Hose

 

 

 

 

60

23.6

 

 

 

cm

 

 

 

inches

 

 

 

 

 

 

1/2" side piping

 

Connecting

 

 

 

cable

 

1/4" side piping

 

 

 

Drain Hose

5

Page 6
Image 6
Daewoo DSB-071LH, Split Airconditioning System owner manual Installation Diagram, Overview, Notes