Tricity Bendix TBG 750 manual Commissioning, Conversion from Natural Gas to LPG

Models: TBG 750

1 16
Download 16 pages 6.05 Kb
Page 15
Image 15
Commissioning

Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

- Turn the gas tap to the MAX position and ignite.

- Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the

procedure below.

 

Procedure:

 

Re-ignite the burner and set to MIN.

Minimum adjustment screw

ΦRemove the control knob.

 

To adjust, use a thin bladed screwdriver and turn

 

the adjustment screw until the flame is steady

 

and does not extinguish, when the knob is turned

 

from MIN to MAX. Repeat this procedure for all

 

burners.

 

Pressure Testing

 

Remove left hand pan support and front left burner

 

Φcap and crown.

 

Fit manometer tube over the injector.

 

Turn on the burner gas supply and ignite another

 

burner.

 

The pressure reading should be nominally 20mbar

 

and must be between 17 mbar and 25mbar.

 

Turn off the burner supplies.

 

Conversion from Natural Gas to

LPG

It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. The gas rate is adjusted to suit.

Method

Ensure that the gas taps are in the 'OFF' position

Isolate the hob from the electrical supply

Remove all pan supports, burner caps, rings, crowns and control knobs.

With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors.

TO ADJUST THE GAS RATE

With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw, which is located down the centre of the gas tap control shaft. Upon completion stick the replacement rating plate on the under side of the hob.

IMPORTANT

The replacement/conversion of the gas hob should only be undertaken by a competent person.