200204171 LR604 Owner’s Manual.qxd 5/30/02 10:53 AM Page 3
Quick Installation
1Connect your equipment to the line conditioner, and the line conditioner to an electrical outlet.
1)Unplug your computer’s power cord from both your AC outlet and your computer’s AC input.
2)Insert the line conditioner’s cord’s (A) female plug into your computer’s AC input. Insert its male plug into any of the line conditioner’s output receptacles.
3)Insert the female plug of your computer’s cord (B) into your line conditioner’s AC input. Insert its male plug into your AC outlet.
2Plug your computer and electronics into your line conditioner’s outlets.
3Turn your line conditioner’s power switch on.
A | B |
1 |
|
2 |
3 |
Basic Operation
Indicator Lights
Your line conditioner has up to 3 indicator lights. All indicator light descriptions apply when the line conditioner is plugged into a wall outlet and turned on. Note: As the line conditioner corrects high or low input voltage, the unit will make a gentle clicking sound. The frequency of the clicking will depend on the quality of the utility power in your particular area. The clicking is normal, and no action is required on your part.
Boost
Normal
Trim
BOOST (Multiple LED Models Only): This yellow light will turn ON whenever your line conditioner is boosting low AC line voltage up to nominal voltage levels.
NORMAL (Multiple LED Models Only): This green light will turn ON whenever your line conditioner is receiving normal AC line voltage.
TRIM (Multiple LED Models Only): This yellow light will turn ON whenever your line conditioner is trimming high AC line voltage down to nominal voltage levels.
3