“SMART” RS-232 Port

The RS-232 port connects your UPS to any workstation or server. Use with Tripp Lite software and included cable to monitor and manage network power and automatically save open files and shut down equipment during a blackout. This port uses RS-232 communications to transmit UPS and power conditions (Pin 7 = Transmit; Pin 8 = Common; Pin 9 = Receive). Contact Tripp Lite Customer Support for more information and a list of available SNMP, network management and connectivity products.

Battery Replacement Door

Under normal conditions, the original batteries in your UPS will last several years. Battery replacement should only be performed by qualified service personnel. Refer to “Battery Warnings” in the Safety section on page 2. When replacing batteries, qualified service personnel should follow this procedure: 1) turn UPS OFF; 2) remove the battery door located on the front panel; 3) pull batteries partially out of the case;

4)make a detailed sketch of the batteries and the polarity, color and connection of all cables; 5) disconnect battery terminals; 6) dispose of used batteries; 7) reconnect replacement batteries exactly as original batteries were; 8) push batteries back into case and replace cover.*

*You may not receive full runtime until your replacement batteries have fully charged.

Storage & Service

Storage

Turn your UPS OFF: first, engage the ON/Standby Switch and release it to place your UPS in the “Standby” mode; then set the System Enable Switch to “DISABLE”; finally, disconnect the UPS power cord from the wall outlet. If you plan on storing your UPS for an extended period of time, recharge the UPS batteries once every three months. Follow steps #1 and #3 in the Installation section and allow the UPS to charge from 4 to 6 hours. If you leave your UPS batteries discharged for an extended period of time, they will suffer permanent loss of capacity.

Service

If returning your UPS to Tripp Lite, please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit. Enclose a letter describing the symptoms of the problem. If the UPS is within the 2 year warranty period, enclose a copy of your sales receipt.

Specifications

 

NP700RM

Output Capacity (VA/Watts):

700/450

Battery Runtime (Half Load/Full Load) Min.:

28/12

Battery Recharge Time:

2-4 hrs.

Suggested Circuit:

15 amp

Approvals:

UL, cUL, FCC Class B

Input Voltage/Frequency (120V/60 Hz); On Line Input Voltage Range (87 - 140 Volts); Voltage-Regulated Output Voltage Range (120V +/- 9%); On Battery Output Voltage Range (120V +/- 5%); Output Waveform Line Mode (filtered sinewave); Output Waveform Battery Mode (PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB); AC Protection Modes (H to N, H to G, N to G).

FCC Radio/TV Interference Notice

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may causeinterference toradio communications. However,thereisnoguaranteethatinterferencewill notoccurin aparticularinstallation.If thisequipment doescause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference using one or more of the following measures: reorient or relocate the receiving antenna; increase the separation betweentheequipmentandreceiver;connecttheequipmentintoanoutletonacircuitdifferentfromthatwhichthereceiverisconnected;consult the dealer or an experienced radio/television technician for help. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user's authority to operatetheequipment.

The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change.

6

Page 6
Image 6
Tripp Lite 700 RM UPS owner manual Storage & Service, Specifications