6712 Controller: Electrical Specifications

6712FR Refrigerated Sampler

Section 1 Introduction

Table 1-3 Technical Specifications for the 6712FR Refrigerated Sampler (Continued)

Weight of Power Pack:

6.0 lbs (2.7 kg)

 

 

 

 

 

 

Weight of Battery Backed Power

6.6 lbs (3.0 kg)

 

 

Pack:

 

 

 

 

 

 

Controller Dimensions:

Length: 10.3 in (26.0 cm)

 

 

Width: 12.5 in (31.7 cm)

 

 

Height: 10 in (25.4 cm)

 

 

 

 

Temperature Ranges:

Operational: 32 to 120 °F (0 to 49 °C)

 

 

Storage: 0 to 140 °F (–18 to 60 °C)

 

 

 

 

 

Maximum Altitude:

2,000 Meters

 

 

 

 

 

 

Installation Category:

II

 

 

 

 

 

 

Pollution Degree:

2

 

 

 

 

 

 

Humidity:

95% RH Maximum

 

 

 

 

 

Enclosure:

NEMA 4X and 6

Pump: IP17 Enclosure: IP67

 

 

Typical Delivered

(The ability to deliver the programmed sample volume.)

Volume Accuracy:

±10 ml or ±10% of programmed value, whichever is greater.

 

 

Typical Repeatability:

(The ability to repeat the delivered volume for a set of samples collected under

 

the same conditions.)

 

 

±5 ml or ±5% of the average of the maximum and minimum sample volume in a

 

sample set, whichever is greater, at lifts up to 25 feet.

 

 

 

 

Typical Pump Flow Rate and

Suction Head

Flow Rate

Line Transport Velocity

Line Transport Velocity:

3 feet

3.9 liters per minute

3.0 ft/s (0.91 m/s)

 

 

5 feet

3.9 liters per minute

3.0 ft/s (0.90 m/s)

 

10 feet

3.7 liters per minute

2.9 ft/s (0.87 m/s)

 

15 feet

3.6 liters per minute

2.7 ft/s (0.83 m/s)

 

20 feet

3.3 liters per minute

2.5 ft/s (0.77 m/s)

 

23 feet

3.1 liters per minute

2.3 ft/s (0.71 m/s)

 

25 feet

2.8 liters per minute

2.2 ft/s (0.66 m/s)

 

 

Maximum Suction Head:

(The maximum suction head is the vertical height at which a sample can be

 

taken.)

 

 

 

28 ft (8.5 m) at 30 inHg (762 mmHg)

 

 

 

Pump Tube Life:

Tube life may vary depending on the abrasiveness of the sample liquid.

 

Recommended maximum 1,000,000 pump counts. This equates to 912 stan-

 

dard samples. A standard sample is 200 ml at 5 ft (1.5 m) suction head using a

 

10 ft (3 m) vinyl suction line.

 

 

 

 

6712 Controller: Electrical Specifications

 

Controller Internal Battery:

5 years minimum (maintains internal logic, program settings & stored data)

 

 

 

 

Real Time Clock Accuracy:

1 minute per month

 

 

 

 

 

Program Memory:

Nonvolatile programmable Flash.

 

 

Can be field updated via interrogator connector.

 

 

 

Sampler Power Requirements:

Nominal: 12 volts DC supplied by the refrigerator

 

Operational: 11 to 13 Volts DC

 

 

Absolute Maximum: 14.4 Volts DC

 

 

 

 

Power Pack Requirements:

120VAC ±12VAC, 60 Hz., 1.0 Amp.

 

Use only Isco-made power

Note: This is the only version certified by UL. The line cord (mains

packs certified by UL.

connect cable) is the “Disconnect Device.”

 

(P/N 60-1684-088)

 

 

 

 

 

 

 

 