Teledyne manual 6712FR Refrigerated Sampler Programming Introduction, Entering Times and Dates

Models: 6712FR

1 244
Download 244 pages 57.15 Kb
Page 50
Image 50
Entering Times and Dates

6712FR Refrigerated Sampler Section 3 Programming Introduction

Entering Times and Dates

ENTER TIME AND DATE:

HH:MM DD-MON-YY

__:__ __-__-__

•Move from one field to another by pressing the arrow keys.

•Change a setting in a field by typing a number. Press to accept the new setting.

3.4.1Setting the Clock and Calendar

When setting the clock and calendar, use a 24-hour clock for times and the day-month-year format for dates. The illustration at the left shows blanks for each position that accepts an entry. The positions are called fields. When this screen appears on your sampler, the fields will contain the sampler’s current settings for the time and date.

To move from one field to another without changing the setting, press the arrow keys. Use this technique when you want to change only one or two settings.

Change the setting by typing a new number. Press ↵ to accept the new setting.

For example, to enter 2:00 p.m. (2:00 p.m is 14:00 on a 24-hour clock), type 14. Press ↵. Next, type 0 (zero) for the minutes, and press ↵. To enter a date, such as January 22, 2001, type: 22 ↵ 01 ↵ 01 ↵ .

1

2

3

4

5

RUN

PROGRAM

VIEW REPORT

OTHER FUNCTIONS

MAINTENANCE

MANUAL FUNCTIONS PROGRAMMING STYLE

SET CLOCK

PUMP TUBE ALARM INTERNAL BATTERY DIAGNOSTICS

ENTER TIME AND DATE:

HH:MM DD-MON-YY

14:00 22-JAN-01

SET CLOCK

PUMP TUBE ALARM INTERNAL BATTERY DIAGNOSTICS

Select OTHER FUNCTIONS.

Select MAINTENANCE.

Select SET CLOCK.

Enter the time and date.

Press Stop to return to the main menu.

3.4.2Menu Screens: Clock There are four start time settings you can use in a sampling

Start Times

program. This section discusses only one of these settings, the

 

clock start time. A clock start time lets you set up a sampling

 

program that starts at the same time on one or more days of the

 

week. For example, you may want to begin sampling at 6:00 a.m.

 

on Monday through Friday (refer to the screen below).

 

To select a day or days from the menu:

1. Press an arrow key until the cursor is on the correct day. Then, press ↵.

2. Repeat these steps until each day you want is blinking.

3. Press an arrow until DONE blinks. Press ↵.

3-6

Page 50
Image 50
Teledyne 6712FR Refrigerated Sampler Programming Introduction, Entering Times and Dates, Setting the Clock and Calendar