Teledyne manual 6712FR Refrigerated Sampler Introduction

Models: 6712FR

1 244
Download 244 pages 57.15 Kb
Page 28
Image 28
145 lbs (66 kg) Refrigerator only, no controller or bottle configuration

6712FR Refrigerated Sampler

Section 1 Introduction

Table 1-3 Technical Specifications for the 6712FR Refrigerated Sampler (Continued)

Dry Weight:

145 lbs (66 kg) Refrigerator only, no controller or bottle configuration

 

160 lbs (73 kg) Includes refrigerator, controller, top cover, center section, tub,

 

pump tube, distributor shaft extension, distributor arm and nut, and discharge

 

tube for the 24 plastic bottle configuration.

 

 

 

 

Dry Weight With:

24 plastic bottles, rack, hold down, no caps

175 lbs(79 kg)

 

24 glass bottles, rack, expander ring, no caps

195 lbs(88 kg)

 

12 plastic bottles, rack, hold down, no caps

175 lbs(79 kg)

 

8 plastic bottles, rack, adaptor, no caps

170 lbs(77 kg)

 

8 glass bottles, rack, adaptor, no caps

180 lbs(82 kg)

 

2 plastic bottles, rack, no caps

175 lbs(79 kg)

 

2 glass bottles, rack, no caps

165 lbs(75 kg)

 

1-9.4 l plastic bottle and cap, no distributor arm or nut165 lbs(75 kg)

 

1-9.4 l glass bottle and cap, no distributor arm or nut

170 lbs(77 kg)

 

1-15.0 l plastic bottle and cap, no distributor arm or nut165 lbs(75

 

kg)

 

 

 

 

1-20.5 l plastic bottle and cap, no distributor arm or nut165 lbs(75

 

kg)

 

 

 

 

1-18.5 l glass bottle and cap, no distributor arm or nut 170 lbs(77 kg)

 

 

 

 

Filled Bottle Weight:

24 plastic bottles

101 lbs(46 kg)

 

 

24 glass bottles

104 lbs(48 kg)

 

 

12 plastic bottles

89 lbs

(41 kg)

 

 

12 glass bottles

95 lbs

(43 kg)

 

 

8 plastic bottles

84 lbs

(38 kg)

 

 

8 glass bottles

90 lbs

(41 kg)

 

 

4 plastic bottles

98 lbs

(45 kg)

 

 

4 glass bottles

104 lbs(48 kg)

 

 

1 plastic bottle

90 lbs

(41 kg)

 

 

1 glass bottle

94 lbs

(43 kg)

 

 

 

 

 

 

Average Thermal

R-16

 

 

 

Resistance Factor:

The average R-value for a complete FR refrigerator not running

 

 

 

 

 

 

 

 

Recovery time

5 minutes

 

 

 

 

 

 

 

 

Recovery time is the time for the internal air temperature to return to 39°F (4°C) after the door has been opened for one minute. The empty refrigerator is running and set at 39°F (4°C). The door is opened at least 4 minutes after the compressor has turned on. Ambient air temperature is 75°F (24°C).

Thermostat

Set point range: 32° to 46°F (0° to 8°C)

 

 

Set point accuracy: ±1.8°F (±1°C) at 39°F (4°C)

 

 

[With an ambient air temperature of 75°F (24°C)]

 

 

 

 

Temperature Ranges

Operational: -20° to 120°F (-29° to 49°C)

 

 

Storage: 0° to 140°F (-18° to 60°C)

 

 

 

Environment

Rain and spray resistant, but not watertight. Do not install in locations where the

 

refrigerator’s lower compartment could become submerged.

 

 

 

Electrical

Power Requirements: 120 Volts, 60 Hz

230 Volts, 50 Hz

 

 

 

(optional)

 

Running current:

3.5 amp

1.75 amp

 

Starting current:

17 amp

8.5 amp

 

Stalled Compressor current:21 amp

10.5 amp

 

(maximum)

 

 

 

 

 

 

1-12

Page 28
Image 28
Teledyne 6712FR Refrigerated Sampler Introduction, lbs 66 kg Refrigerator only, no controller or bottle configuration