Section 4 Standard Programming

 

 

6712FR Refrigerated Sampler

 

 

Section 4 Standard Programming

 

 

 

4.8.3

View Data

This option allows you to view the data recorded by the sampler.

 

 

See Reports on page 4-18for more information.

4.8.4

Grab Sample

When selected, you will be asked to enter the volume to be

 

 

pumped. A sample will then be taken as if it is to be placed into a

 

 

container outside the sampler. Do this by removing the pump

 

 

tubing from the bulkhead fitting. See Grab Samples on page

 

 

4-14.A grab sample event will be logged.

4.8.5

Pump Tube Alarm

If the pump tube is changed, this option should be selected to

 

 

reset the pump counts on the counter. This will remove the

 

 

“WARNING: REPLACE PUMP TUBING” message that may

 

 

appear while the program is running. A pump tube replaced

 

 

message is logged. See Replacing The Pump Tube in Section 7,

 

 

Maintenance.

4.8.6

Calibrate Volume

When selected, you will be asked to enter the volume to be

 

 

pumped. A sample will then be taken as if it is to be placed into a

 

 

container outside the sampler base. Do this by removing the

 

 

pump tubing from the bulkhead fitting.

After the sample has been pumped, you will then be asked to enter the amount actually delivered. Once you have entered the delivered volume and accepted the calibration, a volume delivered event will be logged.

4.8.7Cal/Adj Parameters When the sampler is configured for operation with a module, this option becomes available. Selecting this option will display the appropriate level adjustment screens and/or the calibration screens. If the level is adjusted, an adjusted level event is logged. If a parameter is calibrated, an appropriate event is logged.

Calibrating a parameter probe will temporarily “turn off” the partition data storage and the sample enable/disable functions. These functions are disabled during the calibration and for five minutes after the program is resumed. During this time, parameter data normally collected at the data storage interval will be logged as a 252 error message.

4.8.8 Adjust Pacing

This option is available when the running program is paced by

 

Time, Flow Pulses or Flow Volume. If you select this option, you

 

are asked to enter a new pacing interval. The sampler logs an

 

interval changed event.

 

The original pacing interval continues to count down until you

 

return the sampler to the running program (select resume

 

program). If the new pacing interval is less than the original

 

count remaining, the new interval is used.

 

If the original count remaining is less than the new pacing

 

interval, the original count will continue to count down to the

 

next sample event. Subsequent samples are then paced by the

 

new interval.