1 Operating Mode Switch: controls Inverter/Charger operation. When this switch is set to AUTO, connected equipment receives constant, uninterrupted utility AC power, with simultaneous charging of connected batteries. The CHARGE ONLY setting prevents unwanted battery rundown when there is no need for battery backup. Connected batteries are recharged. When the Operating Mode Switch is set to DC OFF, both the inverter and the battery charger are shut off. However, the unit will still pass utility AC power to connected equipment if it is plugged into an AC outlet.

2 Operation Indicator Lights: These intuitive “traffic light” signals show whether the Inverter/Charger is operating from AC line power or from DC battery power. They also signal an alert if the connected equipment load is too high. See Page 5A for details.

3Battery Indicator Lights: These “traffic light” signals show the approximate charge level of your battery. See page 6A for details.

4AC Input Cord: Connects the Inverter/ Charger to any source of utility- or generator-supplied AC power. See page 10A for connection instructions. (Cord not shown.)

5 AC Receptacle: Permits connection of equipment that would normally be plugged into a utility outlet. Note: The unit will always pass AC power to connected equipment if plugged into a live AC outlet, regardless of the position of the Operating Mode Switch.

6Resettable Circuit Breaker: Protects the Inverter/Charger against damage due to overload. See page 6A for resetting instructions.

7Low Line Set Dial: Adjusts the AC input voltage at which the Inverter/Charger will switch from utility AC power to inverted battery power. If this dial is set fully counterclockwise, the unit will allow AC input to drop to approximately 85V before switching to inverter mode. Note: The unit will continue to pass lower-voltage AC utility power to connected equipment until the unit switches to inverter mode.

8DC Power Terminals: Connect to your battery terminals with user-supplied cabling. See page 9A for connection instructions.

9 Cooling Fan: Regulates internal temperature and prolongs equipment service life. Fan runs intermittently depending on temperature and load.

10 Main Ground Lug: Properly grounds the Inverter/Charger to earth ground or vehicle grounding system. See page 9A for connection instructions.