Specifications

MODEL NUMBER:

PV1000HF

PV1800HF

PV3000HF

Continuous Power (@ 20° C):*

1000

Watts

1800

Watts

3000

Watts

Double Boost™ Peak Surge Power:* 2000

Watts

3600

Watts

6000

Watts

DC Input Volts (Nominal):

12 VDC

12 VDC

12 VDC

DC Input Voltage Range:

10 - 15 VDC

10 - 15 VDC

10.5 - 15 VDC

DC Input Connection:

User Supplied Cables

User Supplied Cables User Supplied Cables

Output Volts (Nominal):

120

VAC

120

VAC

120

VAC

Output Frequency (Nominal):

60 Hz, ± 0.5%

60 Hz, ± 0.5%

60 Hz, ± 0.5%

Efficiency:

Up to 94%

Up to 94%

Up to 94%

Output Waveform:

Modified Sine Wave

Modified Sine Wave

Modified Sine Wave

*DoubleBoost duration (instantaneous). Actual output depends on battery age, battery charge level and ambient temperature. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.

This product designed and engineered in the USA.

Minimum Recommended Cable Sizing Chart

Always loosely twist each pair of cables (one positive and one negative) together.

Use in conjunction with DC wiring connection instructions in the Battery Connection section.

Using 4 conductors is recommended (but not required) to obtain

maximum output power from PV3000HF models.

Wire Gauge

 

 

 

2 Conductors

 

 

4 Conductors

 

 

 

(all models)

 

 

(PV3000HF only)

 

 

 

 

 

 

 

 

Watts

6

4

 

2

0

00

Twin 00

500

15 ft

25 ft

 

39 ft

62 ft

79 ft

158 ft

700

11 ft

18 ft

 

28 ft

44 ft

56 ft

112 ft

1000

N/R

12 ft

 

20 ft

31 ft

39 ft

78 ft

2000

N/R

N/R

 

N/R

16 ft

20 ft

40 ft

2400

N/R

N/R

 

N/R

13 ft

16 ft

32 ft

3000

N/R

N/R

 

N/R

10 ft

13 ft

26 ft

N/R = Not Recommended. NOTE: Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the performance)

Tripp Lite Inverters include a Battery Charge Conserver (Load Sense) Control which saves battery power by allowing users to set the minimum load level at which the unit’s inverter turns on. Users can significantly reduce the No Load DC Input Current to a very low amperage power level with the use of this control.

Important Safety Instructions

SAVE THESE INSTRUCTIONS!

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of allTripp Lite Inverters.

Location Warnings

Install your Inverter in a location or compartment in your vehicle that minimizes exposure to heat, dust, direct sunlight and moisture. Flooding the unit with water will cause it to short circuit and could cause personal injury due to electric shock.

Leave a minimum of 2" clearance at front and back of the Inverter for proper ventilation. To avoid overheating the Inverter, any compartment that contains the Inverter must be properly ventilated with adequate outside air flow. The heavier the load of connected equipment, the more heat will be generated by the unit.

Do not install the Inverter directly near magnetic storage media, as this may result in data corruption.

Do not install near flammable materials, fuel or chemicals.

Battery Connection Warnings

Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.

Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be installed in a “dead air” compartment. Ideally, any compartment would have some ventilation to outside air.

Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.

Do not allow objects to contact the DC input terminals. Do not short or bridge these terminals together. Serious personal injury or property damage could result.

Ground Connection Warnings

Safe operation requires connecting the Inverter's Main Ground Lug directly to the frame of the vehicle or earth ground.

For protection against possible electrical shock hazards, if the Inverter is operated in wet or damp conditions, a user-supplied, portable GFCI (ground fault circuit interruptor) must be connected between each Inverter receptacle and the equipment it powers.

Equipment Connection Warnings

Do not use a Tripp Lite Inverter in life support or healthcare applications where a malfunction or failure of a Tripp Lite Inverter could cause failure of, or significantly alter the performance of, a life support device or medical equipment.

You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of the Inverter.

Operation Warnings

Your Inverter does not require routine maintenance.

Potentially lethal voltages exist within the Inverter as long as the battery supply is connected. During any service work, the battery supply should therefore be disconnected.

Do not connect or disconnect batteries while the Inverter is operating from the battery supply. Dangerous arcing may result.

2PV

Page 2