Section Maintenance
5
SPECIFICATIONS
Maximum Surge Watts . . . . . . . . . . . . . . . . . .8,550 watts Continuous Wattage Capacity . . . . . . . . . . . .5,550 watts Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0 Rated Maximum Continuous AC Load Current:
At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .46.2 Amps At 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . .23.1 Amps
GENERAL MAINTENANCE RECOMMENDATIONS
The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a
damaged or defective generator.
Should you have questions about replacing components on your
NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
Generator Cleaning
• Use a damp cloth to wipe exterior surfaces clean.
CAUTION
Improper treatment of generator can damage it and shorten its life.
•DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
•DO NOT insert any objects through cooling slots.
•Use a soft bristle brush to loosen caked on dirt or oil.
•Use a vacuum cleaner to pick up loose dirt and debris.
•Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator. These openings must be kept clean and unobstructed.
Engine Maintenance
See engine owner’s manual for instructions.
CAUTION
Avoid prolonged or repeated skin contact with used motor oil.
•Used motor oil has been shown to cause skin cancer in certain laboratory animals.
•Thoroughly wash exposed areas with soap and water.
Data Tag
Data tag information is very important if you need help from our Customer Service Department or an authorized service dealer.
•The data tag (Figure 9) is located either on the heat shield or engine support on the muffler side of the generator. For future reference, please copy the model, revision, and serial number of the generator in the space below.
Figure 9 — Data Tag
KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.
MODEL REV NO SERIAL
AC VOLTS AC AMPS AC WATTS DC VOLTS DC AMPS
Copy Model
Number Here
Copy Revision
Here
Copy Serial Number Here
12