Symptom | Probable Cause | Corrective Action | Recommended Tools |
NO CONTACT HEART RATE 750E, 750EA
Dirty Sensors
Console Set/
Wiring
Wire Connections
•Verify hand pulse sensors are clean.
•Set meter for continuity.
•Remove Console set.
•Check for continuity in both sets of hand pulse sensors between the console set and hand pulse sensor plates.
•If continuity is OK – Replace Console set. If no- continue on.
•Check wire connections @ handlebar console mast joint
•Check connections of wires to hand pulse sensor by removing hand pulse sensor plates.
•To remove hand pulse sensor plates carefully pry under one end to free them from the plastic handgrips.
•Bad connections? - Reconnect/ Replace bad wires.
•Recheck continuity.
Note:
You must pedal at least 30 RPM when performing any voltage test. You may require the assistance of another person when performing voltage checks.